background image

 

 

 
 

CCA 

 

370001 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access controller 

 
 
 
 

 

 

 

EN 

Installation manual 

 

 

Содержание EKSELANS 370001

Страница 1: ...CCA 370001 Access controller EN Installation manual ...

Страница 2: ... controller It allows to control the voltage that feeds the lock from an external source either AC or DC Allows the connection of a button push button for instant door opening Users registered in a controller can be cloned in other controllers Supports up to 1000 users Compatible with Wiegand readers Allows management by remote control 2 Accessories 1x Remote control keyboard 1x Master card to add...

Страница 3: ... DC voltage In case of powering the controller with alternating current connect the source to the terminals indicated as AC and AC In case of powering the controller with direct current connect the source to the terminals indicated as GND and DC Respect the polarity Check the maximum rating voltage in the technical specification 4 2 Door opener voltage feeding The controller may act on the door op...

Страница 4: ... supplied diode directly in the door opener in the case that it supplies the lock with direct voltage DC Do not use the diode in case of powering the system in AC Respect the polarity of the diode as indicated 5 Installation Below there are two typical installations with their connection and configuration Configuration in Input Pass the same voltage that feeds the controller will feed the lock Con...

Страница 5: ...With the remote control you can force a card to have a specific identifier leaving bubbles if desired There cannot be two user cards with the same identifier It is recommended to register the identifier by relating it to the serial number of the card and to the user of the card It is not recommended to write down the identifier on the card itself Should it be lost the identifier to be removed from...

Страница 6: ...elete a user card by reading it with the card reader Not lost card Step 1 Enter in the programming mode Master code Step 2 Sweep the card to be unsubscribed This position will be empty 2 Sweep card Step 3 Exit the programming mode Note that a bubble can be been created There can be an empty identifier position not linked with a user card To delete a user card from a specific position The card is l...

Страница 7: ...the programming mode Master code Step 2 Start the transfer 9 6 Step 3 Wait until the transmission ends The green LED blinks Step 4 Exit the programming mode Note that Both units must have the same master code A cloning process with 1000 registered users may last up to 3 minutes Check connections Avoid short circuits 6 3 Programming via master cards By using the master cards it is possible to subsc...

Страница 8: ...s Subscribing Step 1 Sweep MASTER ADD card Step 2 Sweep the user card More user cards may be swept A sound will be heard Step 3 Sweep MASTER ADD card Unsubscribing Step 1 Sweep MASTER DELTE card Step 2 Sweep the user card More user cards may be swept A sound will be heard Step 3 Sweep MASTER DELETE card 6 4 Restore to factory default values The following process restores the original default facto...

Страница 9: ...minal AC V rms 12 30 24 DC Vdc 9 24 12 Consumption Stand by Maximum AC mA rms 115 170 DC mA 60 80 Output voltage For LCA Vdc 12 Maximum switching current A 1 Maximum distance IR Keyboard m 10 Working temperatura ºC 40 60 Working humidity Hum 0 90 Dimensions mm 90 x 63 x 22 Including reader excluding door opener Depending on Ilumination battery ...