RECEIVER IT3R10
USER MANUAL
6
4. TECHNICAL SPECIFICATIONS
SYSTEM:
MULTIFREQUENCY
FREQUENCY:
ISM-BAND
ORDER REPONSE TIME:
<50 ms
ACTIVE EMERGENCY TIME:
<50 ms
PASIVE EMERGENCY TIME:
1600 ms
RANGE OF ACTION:
100 meters
Frequency bands:
433.050 to 434.775 MHz
(I-ETS 300 220)
868.000 to 870.000 MHz
Temperature range:
From -20ºC to +70ºC
Available Manoeuvres:
10 2 STOP RELAYS (Optional 11 + 2 relays)
Max. capacity
Relay switching:
Resistive load:
Inductive load: (cosØ=0,4)
5 A to 250 Vac or 30 Vdc
2 A to 250 Vac or 30 Vdc
Power supply:
(according to the
model)
48 Vac / 230 Vac (-20% + 15%) according to EN 60047-5-1
48 Vac / 115 Vac (-20% + 15%) según EN 60047-5-1
115 Vac / 230 Vac (-20% + 15%) según EN 60047-5-1
24 Vac / 230 Vac (-20% + 15%) según EN 60047-5-1
24 Vac / 24 Vdc (-20% + 15%) según EN 60047-5-1
12 Vdc (-20% + 15%) según EN 60047-5-1
Max consumption:
0,03 A (230 Vac)
0,05 A (115 Vac)
0,1 A (48 Vac)
0,155 A (24 Vac)
0,135 A (24 Vdc)
0,160 A (12 Vdc)
Fuses:
Emergency Stop Operation: 3 A
Connection:
Through a 26- pins Itowa connector
Dimensions:
External: 190 x 83 x 165 mm
Weight:
With fastening: 890 g.
Fastening:
With bolts, DIN rail or magnetic (optionally)
Protection:
IP65
Safety level
Category 4
– SIL3/PLe according to EN ISO 13849