Itowa IT3R10 Скачать руководство пользователя страница 6

RECEIVER IT3R10 

USER MANUAL 
 



4. TECHNICAL SPECIFICATIONS 

 

 

 

 

 

 

 

 

 

SYSTEM: 

MULTIFREQUENCY 

FREQUENCY: 

ISM-BAND 

ORDER REPONSE TIME: 

<50 ms 

ACTIVE EMERGENCY TIME: 

<50 ms 

PASIVE EMERGENCY TIME: 

1600 ms 

RANGE OF ACTION: 

100 meters 

Frequency bands: 

433.050 to 434.775 MHz 

(I-ETS 300 220) 

868.000 to 870.000 MHz 

Temperature range: 

From -20ºC to +70ºC 

Available Manoeuvres: 

10 2 STOP RELAYS  (Optional 11 + 2 relays) 

Max. capacity   
Relay switching: 

Resistive load: 
Inductive load: (cosØ=0,4) 

5 A to 250 Vac or 30 Vdc 
2 A to 250 Vac or 30 Vdc 

Power supply: 
(according to the 
model) 

48 Vac / 230 Vac (-20% + 15%) according to EN 60047-5-1 
48 Vac / 115 Vac (-20% + 15%) según EN 60047-5-1 
115 Vac / 230 Vac (-20% + 15%) según EN 60047-5-1 
24 Vac / 230 Vac (-20% + 15%) según EN 60047-5-1 
24 Vac / 24 Vdc (-20% + 15%) según EN 60047-5-1 
12 Vdc (-20% + 15%) según EN 60047-5-1 

Max consumption: 

0,03 A (230 Vac) 
0,05 A (115 Vac) 
0,1 A (48 Vac)   
0,155 A (24 Vac) 
0,135 A (24 Vdc)  
0,160 A (12 Vdc) 

Fuses:  

Emergency Stop Operation: 3 A 

Connection: 

Through a 26- pins Itowa connector 

Dimensions: 

External: 190 x 83 x 165 mm 

Weight: 

With fastening: 890 g. 

Fastening: 

With bolts, DIN rail or magnetic (optionally) 

Protection: 

IP65 

Safety level 

Category 4 

– SIL3/PLe according to EN ISO 13849 

Содержание IT3R10

Страница 1: ...User Manual MARI10EN Rev 1 05 2020 Receiver IT3R10 EN nS...

Страница 2: ...RODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITO...

Страница 3: ...RECEIVER 5 4 TECHNICAL SPECIFICATIONS 6 5 INSTALLATION AND START UP 7 5 1 INSTALLATION OF THE RECEIVER 7 5 1 1 FASTENING OPTIONS 7 5 2 CONNECTING 7 5 3 START UP 9 6 MAINTENANCE 10 6 1 MAINTENANCE OF...

Страница 4: ...y and at random thereby avoiding interferences which could cause continuous downtimes during operation The receiver works in the UHF band at frequencies between 433 050 and 434 775 MHz or between 868...

Страница 5: ...for each operation of the crane FM radio modulation and FFSK coding are used for radio transmission of control signals The control module is in charge of verifying that the information received is fr...

Страница 6: ...2 A to 250 Vac or 30 Vdc Power supply according to the model 48 Vac 230 Vac 20 15 according to EN 60047 5 1 48 Vac 115 Vac 20 15 seg n EN 60047 5 1 115 Vac 230 Vac 20 15 seg n EN 60047 5 1 24 Vac 230...

Страница 7: ...na it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS For the magnetic fastening option it should be placed on a met...

Страница 8: ...ATION AT TERMINALS 24 AND 26 1 This relay can be configured as N C Normally Close through the bridge located on the back of the board 2 For other power supplies please see the attached documents provi...

Страница 9: ...lowing steps will be done with the transmitter associated with the receiver Insert a charged battery into the transmitter set release the STOP BUTTON and press the START 1 button The remote control wi...

Страница 10: ...BEFORE HANDLING THE TRANSMITTER TURN OFF THE GENERAL SWITCH OF THE MACHINE 6 1 MAINTENANCE OF THE RECEIVER During maintenance of the receiver the following parts will be checked The connection between...

Страница 11: ...rting with LED S1 with the first digit of the code reading from left to right The following table indicates the correspondence between the hexadecimal value of each digit and the number of flashes tha...

Страница 12: ...STATE LED S2 Stand by mode or operation without changes Fault in Stop relays Flashing for each change of state in one of the relays STATE LED S3 Not used STATE LED S4 EEPROM Ok Error in EEPROM STATE...

Страница 13: ...to the electrical panel of the machine using the corresponding connectors The set is connected to the machine but it does not work The power supply of the set is under 45 of the nominal value The set...

Страница 14: ...ns avoiding possible negative consequences for the environment resulting from improper disposal And also allows a treatment and recycling of the materials that compose it obtaining important savings i...

Страница 15: ...RECEIVER IT3R10 USER MANUAL 15 www itowa com SINDITO S L Faraday 159 08224 Terrassa Barcelona Espa a Tel 34 93 733 98 50...