ITI Quick Bridge 60-615 Скачать руководство пользователя страница 1

Page 1

Quik Bridge Learn Mode Repeater

Quik Bridge™
Learn Mode Repeater

Document Number: 46-849 Rev. G
November 1999

INSTALLATION
INSTRUCTIONS

Product Summary

The purpose of the Quik Bridge Learn Mode Repeater 
is to receive and retransmit signals from Learn Mode 
sensors, wireless touchpads, and other repeaters. The 
repeater is ideal for the following applications:

n

Installations where sensors are beyond panel
reception or fail sensor test.

n

As a substitute for preamps in installations where
panel antennas are shielded by metal.

The repeater may be used in one of the following 
modes:

Intelligent mode: In this mode, the repeater retrans-
mits signals received from sensors, wireless touch-
pads, and intelligent mode repeaters that have been 
“learned” into the repeater memory. An intelligent 
mode repeater may “learn” a maximum of 16 sensors/ 
touchpads and 2 intelligent mode repeaters.

Sensor mode: In this mode, the repeater will retrans-
mit all signals received from sensors and wireless 
touchpads but will not retransmit signals received 
from other repeaters. 

Repeater Features

Repeater features include the following:

n

Transmittal of hourly supervisory reports to the 
panel.

n

A tamper switch that causes an alarm transmis-
sion if the repeater cover is removed.

n

Support for a rechargeable backup battery.

n

A dual-antenna receiver, which improves recep-
tion through spatial diversity.

n

Transmittal of a low battery trouble report when 
the backup battery is low (optional).

n

Transmittal of an AC power failure alarm when 
AC power has failed for more than 15 minutes 
(optional).

n

Learn Mode technology, making installation 
easy.

Powering Options

n

15–16.5 VAC Class II Transformer with 2 VA rat-
ing or higher, when using a backup battery.

or-- 9–16.5 VAC Class II Transformer with 2 VA rat-

ing or higher, when not using a backup battery.

or-- 12 VDC supply.

Compatibility

n

All current ITI Learn Mode sensors (except RF 
Meterlink) and wireless touchpads.

n

CareTaker

®

 Plus, WatchGard, and Security Pro 

4000 panels with software version 4.0 or later.

n

SX-V Special with software version 7.0 or later.

n

Safewatch Custom RF with software version 2.1 
or later.

n

UltraGard™ with software version 1.0 or later.

Tools and Accessories Needed

Included with Repeater

n

Mounting screws and anchors

60-615

8884G01A.DS4

Содержание Quick Bridge 60-615

Страница 1: ...er repeaters Repeater Features Repeater features include the following n Transmittal of hourly supervisory reports to the panel n A tamper switch that causes an alarm transmis sion if the repeater cov...

Страница 2: ...igent Mode The intelligent mode is the recommended mode of operation In this mode the repeater only retransmits signals received from sensors touchpads and intelli gent mode repeaters that are learned...

Страница 3: ...over off of the receiving repeater 2 For sensors with a tamper switch remove the cover from the sensor This causes an alarm trans mission and the repeater should receive 7 8 pack ets indicated by 7 8...

Страница 4: ...the repeater receiver Connecting Antennas to the Repeater To connect antennas to the repeater 1 Remove the cover by pressing down on the top center of the cover and pull it away from the base see Fig...

Страница 5: ...per is tripped 3 Trip the repeater tamper when the procedure prompts for the sensor activation Installing an Intelligent Mode Repeater This section describes how to install a single intelli gent mode...

Страница 6: ...eater If the signals from this repeater need to be repeated by another destination repeater then learn this repeater into the destination repeater To learn a source intelligent mode repeater into a de...

Страница 7: ...on DIP Switch 1 2 3 4 5 6 7 8 Learn Transmitter off off on set the repeater number closer Repeat until the repeater passes this test To test signals sent to another intelligent mode repeater n Perform...

Страница 8: ...ED begins to blink 3 Set DIP switches 1 3 to the OFF position after the LED on the repeater starts blinking 4 Press and release the tamper switch again 5 Wait for LED to stop blinking Remove power fro...

Страница 9: ...tallation using intelligent mode repeaters Final Test In order to ensure that sensors and transmitters have been deleted remove power for five seconds and reac tivate it Then perform a sensor and tran...

Страница 10: ...Hold the base against the mounting surface and mark the three mounting holes see Figure 7 Figure 7 Mounting Hole Locations Note Remember to leave at least 10 inches above the repeater for the antenna...

Страница 11: ...er 2 between repeater 1 and a group of dis tant sensors sensors 5 and 6 14 Perform a Repeater Reception Test between repeater 2 and repeater 1 15 Perform a Repeater Reception Test on all remaining dis...

Страница 12: ...ing antennas Notices This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept...

Отзывы: