Page 1
Quik Bridge Learn Mode Repeater
Quik Bridge™
Learn Mode Repeater
Document Number: 46-849 Rev. G
November 1999
INSTALLATION
INSTRUCTIONS
Product Summary
The purpose of the Quik Bridge Learn Mode Repeater
is to receive and retransmit signals from Learn Mode
sensors, wireless touchpads, and other repeaters. The
repeater is ideal for the following applications:
n
Installations where sensors are beyond panel
reception or fail sensor test.
n
As a substitute for preamps in installations where
panel antennas are shielded by metal.
The repeater may be used in one of the following
modes:
Intelligent mode: In this mode, the repeater retrans-
mits signals received from sensors, wireless touch-
pads, and intelligent mode repeaters that have been
“learned” into the repeater memory. An intelligent
mode repeater may “learn” a maximum of 16 sensors/
touchpads and 2 intelligent mode repeaters.
Sensor mode: In this mode, the repeater will retrans-
mit all signals received from sensors and wireless
touchpads but will not retransmit signals received
from other repeaters.
Repeater Features
Repeater features include the following:
n
Transmittal of hourly supervisory reports to the
panel.
n
A tamper switch that causes an alarm transmis-
sion if the repeater cover is removed.
n
Support for a rechargeable backup battery.
n
A dual-antenna receiver, which improves recep-
tion through spatial diversity.
n
Transmittal of a low battery trouble report when
the backup battery is low (optional).
n
Transmittal of an AC power failure alarm when
AC power has failed for more than 15 minutes
(optional).
n
Learn Mode technology, making installation
easy.
Powering Options
n
15–16.5 VAC Class II Transformer with 2 VA rat-
ing or higher, when using a backup battery.
or-- 9–16.5 VAC Class II Transformer with 2 VA rat-
ing or higher, when not using a backup battery.
or-- 12 VDC supply.
Compatibility
n
All current ITI Learn Mode sensors (except RF
Meterlink) and wireless touchpads.
n
CareTaker
®
Plus, WatchGard, and Security Pro
4000 panels with software version 4.0 or later.
n
SX-V Special with software version 7.0 or later.
n
Safewatch Custom RF with software version 2.1
or later.
n
UltraGard™ with software version 1.0 or later.
Tools and Accessories Needed
Included with Repeater
n
Mounting screws and anchors
60-615
8884G01A.DS4