ITI Learn Mode 60-742 Скачать руководство пользователя страница 1

1

Learn Mode Freeze Sensor

Installation Instructions

Document Number: 466-1541 Rev. C
November 1999

ITI Part No. 60-742

Product Summary

The ITI Learn Mode™ Freeze Sensor detects a furnace fail-
ure in a home or business. The Freeze Sensor contains a 
bimetallic switch wired to a transmitter. It activates the 
switch when the surrounding temperature drops to about 
41°F. After the sensor is tripped, the Freeze Sensor will 
send a restore signal to the panel when the temperature rises 
to 50°F.

Tools and Equipment Needed

Slotted screwdriver, if using screws instead of the 
included double-faced tape

The panel installation instructions, for more detailed 
instructions on programming sensors

Ice cube

Plastic bag

Installation Guidelines

Do

Keep the transmitter within 100 feet of the panel. In 
open air, the transmitter has a range of 500 feet, but the 
indoor range will be shorter.

Locate the sensor in an area that is likely to get cold 
first.

Locate the sensor on an interior wall where there is free 
movement of air.

Program and test the Freeze Sensor before you perma-
nently attach it to anything.

Do not

Locate the sensor in the same room as a furnace, water 
heater, or any other heat source that may stay warm 
after the furnace fails.

Locate the sensor on an outside wall or near the base-
ment floor.

Place in areas with excessive metal or electrical wiring; 
these may keep the sensor’s signals from reaching the 
panel.

Place sensor in an area where it will be exposed to 
moisture.

Place sensor in a location where the temperature will 
exceed the sensor’s operating limits of 10° to 120°F.

Programming

Follow these instructions to program the freeze sensor:

1.

Open the control panel cover.

2.

Enter Utility Access Code 1 or 2 using the red-num-
bered buttons.

3.

Press Add from the Start Menu.

4.

Press the Sensor/Remote button from the Main menu 
until you hear the location you wish to use with the sen-
sor.

The order of names the Control Panel uses are: key-
chain remote, touchpad remote, front door, back door, 
garage door, bedroom, guest room, child’s room, util-
ity room, living room, dining room, bathroom, laundry 
room, kitchen, office, den, garage, special chime, 
basement, upstairs, downstairs, hallway, medicine 
cabinet, closet, attic. Each name may be used more 
than once. 

Note

When adding sensors, if you wish to use a more 
descriptive location you may press the option button to 
use the compass directions (north, north east, east, 
south east, south, south west, west, north west).

5.

Press DONE.

6.

Enter the sensor type number (29) with the red num-
bered keys. 

Note

If you wish to use a sensor number other than the next 
available, enter a 2 digit sensor number with the red 
numbered keys immediately after entering the sensor 
type. 

7.

Press the button on the top of the sensor (cover 
removed) until the control panel confirms the program-
ming. If the button is not held down long enough, SYS-
TEM STATUS will report the sensor is open.

Testing

Perform Sensor Test

The following steps describe the guidelines for testing sen-
sors. 