Electrical installation
Page 84
8.4.3
Pin assignment [X6]
Table 34:
Pin assignment: [X6]
Pin No.
Denomination
Values
Specification
1
BR-
0 V brake
Holding brake (motor), signal level
dependent on switch status, high side / low
side switch
2
BR+
24 V brake
3
PE
PE
Connection for inner shield
(holding brake + temperature sensor)
4
MT-
GND
Motor temperature sensor
1)
, N.C. and N.O.
contact, PTC, NTC KTY
5
MT+
+ 3,3 V / 5 mA
6
PE
PE
Motor ground conductor
7
W
0 ... 270 V
RMS
0 ... 230 V
RMS
0 ... 2,5 A
RMS
0 ... 5 A
RMS
0 ... 8 A
RMS
0 ... 1000 Hz
C 1-02 and
C 1-05
C 1-08
C 1-02
C 1-05
C 1-08
Connection of the three motor phases
8
V
9
U
1)
Please comply with
Chapter 9 Additional requirements for the servo drives concerning the UL approval
page 107.
The cable shield of the motor cable must also be connected to the controller housing (PE screw terminal).
8.4.4
Cable type and design [X6]
The mentioned cable denominations refer to cables by Lapp. They have proven effective and are successfully used in many
applications. However, similar cables from other manufacturers, for example Lütze or Helukabel, may also be used.
Caution!
Please comply with the prescribed minimum copper cross-section for cables as per EN 60204-1!
C 1-02:
LAPP KABEL ÖLFLEX SERVO 700 CY; 4 G 1,5 + 2 x (2 x 0,75);
∅
12,7 mm, with tinned total Cu shield
C 1-05 and C 1-08:
LAPP KABEL ÖLFLEX SERVO 700 CY; 4 G 2,5 + 2 x (2 x 0,75);
∅
14,9 mm, with tinned total Cu shield