10.8
Battery ChCBC
Description:
This command returns battery status <bcs> and battery charge level <bcl> of MT.The charge level <bcl> will be
also used to build and display the indicator “battchg” i.e. battery charge level in the response code +CIND and
in the unsolicited result code +CIEV.
The following mapping of “battchg” to <bcl> exists:
“battchg” <bcl>
0 < 17 %
1 < 33 %
2 < 50 %
3 < 67 %
4 < 83 %
5 >= 83 %
•
Execution Command returns battery status <bcs> and battery charge level <bcl> of MT.
•
Test command returns the (list of supported<bcs>’s),(list of supported <bcl>’s)
Syntax:
AT+CBC
Command
Possible Responses
AT+CBC
OK
Or
CME ERROR:<error>
or
AT+CBC=?
+CBC : (list of supported
<bcs>’s),(list of supported <bcl>’s)
OK
Defined Values
<bcs>
Battery Charge Staus
0
=
MT is powered by the battery
1
=
MT has a battery connected, but is not powered by it
2
=
MT does not have a battery connected
3
=
Recognized power fault, calls inhibited
<bcs>
Battery Charge Level
0
=
battery is exhausted or MT does not have a battery connected
1…100 =