background image

Please follow the instructions in this manual to obtain the optimum results from this unit.

We also recommend that you keep this manual handy for future reference.

O

P

E

R

A

T

IO

N

 M

A

N

U

A

L

PUBLIC ADDRESS SYSTEM

CLASS-D AMPLIFIER

T-1D120-1D240-1D350-1D500

T-2D120-2D240-2D350-2D500

T-4D120-4D240-4D350-4D500

POWER

CH1

OFF

ON

T-1D120
CLASS-D AMPLIFIER

PROT

CLIP

SIG

STBY

24V DC

POWER

CH1

CH2

OFF

ON

T-2D120
CLASS-D AMPLIFIER

PROT

CLIP

SIG

STBY

24V DC

POWER

CH1

CH2

CH3

CH4

OFF

ON

T-4D120
CLASS-D AMPLIFIER

PROT

CLIP

SIG

STBY

24V DC

Содержание T-1D120

Страница 1: ...OPERATION MANUAL PUBLIC ADDRESS SYSTEM CLASS D AMPLIFIER T 1D120 1D240 1D350 1D500 T 2D120 2D240 2D350 2D500 T 4D120 4D240 4D350 4D500 POWER CH1 OFF ON T 1D120 CLASS D AMPLIFIER PROT CLIP SIG STBY 24...

Страница 2: ...Front Panel T 2D120 2D240 2D350 2D500 5 3 4 Rear Panel T 2D120 2D240 2D350 2D500 5 3 5 Front Panel T 4D120 4D240 4D350 4D500 6 3 6 Rear Panel T 4D120 4D240 4D350 4D500 6 4 OPERATING INSTRUCTION 7 5 W...

Страница 3: ...r Make no further attempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object get...

Страница 4: ...ects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure th...

Страница 5: ...long term supply for battery failure or damage of high voltage equipment 9 AC alternating current power supply pressure 10 Power amplifier output 100V voltage 11 Electrical equipment electrical isola...

Страница 6: ...ff the power 3 NOMENCLATURE AND FUNCTIONS 3 1 FRONT PANEL T 1D120 1D240 1D350 1D500 3 2 REAR PANEL T 1D120 1D240 1D350 1D500 4 3 11 16 8 2 1 6 7 4 5 9 10 12 13 11 14 15 13 CH1 100V speaker output 14 R...

Страница 7: ...f the power NOMENCLATURE AND FUNCTIONS 3 3 FRONT PANEL T 2D120 2D240 2D350 2D500 3 4 REAR PANEL T 2D120 2D240 2D350 2D500 5 3 11 16 8 2 1 6 7 4 5 9 10 12 13 11 14 15 13 CH1 CH2 100V speaker output 14...

Страница 8: ...LATURE AND FUNCTIONS 3 5 FRONT PANEL T 4D120 4D240 4D350 4D500 3 6 REAR PANEL T 4D120 4D240 4D350 4D500 6 3 11 16 8 2 1 6 7 4 5 9 10 12 13 11 14 15 13 CH1 CH4 100V speaker output 14 Remote Standby cas...

Страница 9: ...ltage range 100V speaker output 1 channels Class D amplifier output with source filters to pass invalid audio signal available for 100V external speaker The total power of the speakers connected to th...

Страница 10: ...or STBY THRU and GND are short cut the main power amplifier will be forced off The machine will turn to standby mode with consumption less than 60W They are electrically connected in parallel you can...

Страница 11: ...nd to have sufficient strength and current carrying capacity thereby ensuring under fault conditions exposed conductive parts will not lead to shock but not because of the current flowing through the...

Страница 12: ...interference of AC power source is not so sensitive And unbalanced lines can cause noise especially when long cable through 2 Connected directly with the constant voltage speaker Speaker output line...

Страница 13: ...T 1 2 3 4 5 6 7 8 9 10 CHIME REMOTE 2 OUTPUTS 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 POWER 24V 2A AUDIO OUTPUT R R L L MIC CD PLAYER PRE AMPLIFIER GND STBY IN GND GND STBY THRU STATE...

Страница 14: ...CH2 CH1 CH2 CH3 CH4 IR S2092S IR S2092S IR S 2092S IR S 2092S IR S2092S IR S2092S IR S2092S IR S2092S BP 00137 BP 00137 BP 00274 BP 00274 PA 01479 PWM PA 01479 PWM PA 01478 DC 18V BP 00137 BP 00137 B...

Страница 15: ...connect other equipments as well Pull up the power line after closing down In a sound system the amplifier should be the first to start up and the last to close down Starting up order First start up...

Страница 16: ...1dB 3dB 85dB 80Hz 16kHz 10dB below maximum power 0 2 1 kHz maximum power 1 85 After a forced air into the front 50 70 Thermostat With short circuit overload over temperature protection output DC 484x4...

Страница 17: ...dB 3dB 85dB 80Hz 16kHz 10dB below maximum power 0 2 1 kHz maximum power 1 85 After a forced air into the front 50 70 Thermostat With short circuit overload over temperature protection output DC 484x44...

Страница 18: ...5dB 80Hz 16kHz 10dB below maximum power 0 2 1 kHz maximum power 1 85 After a forced air into the front 50 70 Thermostat With short circuit overload over temperature protection output DC 484x444 5x65mm...

Страница 19: ...66 74 5 437 484 POWER CH1 CH2 CH3 CH4 OFF ON PROT CLIP SIG STBY 24V DC GND STBY IN GND GND STBY THRU STATE OUT CH1 CH2 CH3 CH4 100V SPEAKER OUTPUT TRIGGER CH1 CH2 CH3 CH4 LINE INPUT VCA CH1 CH2 CH3 CH...

Страница 20: ...PUBLIC ADDRESS SYSTEM VersionV0 1...

Отзывы: