Hemlock
TM
Powered Table Leg Install Instructions
(Part #’s: PACTL-FFLL, PACFB-FFLL & PACTB-FFLL)
For warranty information please visit www.itc-us.com/warranty
Locate the position of the floor base. Care should be taken to evaluate the backside of the mounting surface to ensure that wire
clearances and routing is considered with regards to any supports that are located under the floor. It is also recommended to
evaluate the release button location and the positioning of the wire exit relative to the button.
1.
INSTALLATION CONSIDERATIONS
• To avoid a hazard to children, account for all parts and destroy all packing materials.
•
Do not sit on or lean on table, intended for use as a table only.
•
The stiffness and rigidity of the floor mounting substrate has a direct effect on the sturdiness of the entire table system.
PARTS/TOOLS NEEDED:
#12 Oval Screws
Table & Table Base
Floor Base
Table Leg
(Not Provided)
Power Drill w/ 3/4” Bit
(Not Provided)
WARNINGS
•
Hemlock Powered table legs are only intended to be used with Hemlock Powered floor bases and table bases supplied by ITC, Inc. DO
NOT USE components from Hemlock with components from any other system. If this is not followed, damage to components will occur.
•
Hemlock powered floor bases come with an integral fuse to protect the table leg and table system. Do not cut this fuse off during
installation.
•
The Hemlock Powered table leg system utilizes gold plated contacts to ensure reliable electrical contact over the life of the system.
Contacts should be periodically cleaned to reduce salt or other mineral build up over time, especially in saltwater environments.
•
Hemlock Powered table system is designed to be used with a 10-16VDC environment with a maximum current of 6A.
•
When routing wires, care must be taken to route wires away from sharp objects that can damage electrical wires under vibration. Use
wire restraints and grommets as necessary.
•
The provided floor base cap should be used whenever the leg is not installed to protect the electrical contacts.
Once floor base location and wire entry hole position is located, Using the template, mark the location of the wire entry hole and
mounting screw holes. The wire entry hole should be sized to ¾” to allow in-line fuse to pass through the hole. Mounting screw holes
should be sized appropriately for mounting floor material and screw style. #12 screws are recommended for installation. Drill holes
appropriately.