Страница 3: ......

Страница 4: ......

Страница 5: ...ept Operating the welder and generator set should be carried out on a flat floor If the set is oblique the oil can overflow 2 1 2 Prevent the suction of the exhausted gas At the places with poor ventilation the welder and generator set should not be used If it is necessary to operate the set indoors a suitable ventilation condition should be supplied to prevent the personnel and livestock from the...

Страница 6: ...laces with good ventilation 2 2 Preparation before the Start 2 2 1 Select and treat with the combustion oil Only use the light diesel oil The combustion oil should filtered cleanly Attention should be paid so don t let any dust and water to be mixed into the combustion oil and the oil tank Otherwise the High pressure pump and the oil nozzle may be blocked up ATTENTION z Overflowing the oil is very...

Страница 7: ...ngine is reduced Although there are the low oil pressure alarm system the stop device At the time of starting the set it is necessary to check the oil quantity is not sufficient please add some oil Discharging the machinery oil should be carried out while the diesel engine is hot After the cooling it is very difficult to discharge the oil cleanly WARNING Don t fill the machinery oil into the diese...

Страница 8: ...e filling the fuel oil and starting the diesel engine it is necessary to check whether there is any air mixed into the oil circuit If there is any the air should be discharged The concrete method is to unfasten the connecting nut between the oil injection pump and the oil transmission pipe so discharge the air in the fuel oil until no air bubble appear Then faster the connecting nut again 2 3 Insp...

Страница 9: ...dle till you feel your hand has the resistance force Then relieve it and let it restore to the initial position Press down the pressure reduction handle when the buffer starter is drawn it will automatically be restored Quickly draw out the buffer start handle by two hands While operating or after the start don t let the handle fly out of your hand to avoid that it smashes onto the diesel engine S...

Страница 10: ...l go down to cause the start motor running hysteresis z When the diesel engine is in operation always leave the start key in ON position 2 Battery Check the electrolyte level height of the battery once a month When the liquid level goes down to a lower mark add some distilled water to make that the liquid level goes up to the higher mark If the electrolyte in the battery is too less the diesel eng...

Страница 11: ...DIESEL GENERATOR SET USER S MANUAL 2 5 Operation Procedure for Starting the Generator Set This operation procedure is suitable series recoil hand drawing start mode 9 ...

Страница 12: ... Check whether there is any abnormal sound or vibration Check whether the diesel engine does not start or the operation is not good Check the exhausted gas color Is it black or is it too white If you find one of the above mentioned phenomena it is necessary to brake the set to find out the trouble cause and shoot the trouble If the settlement can not be made please contact agency of our company ne...

Страница 13: ...w or too high the revolution speed can be adjusted If there is any trouble and any abnormal running condition it is necessary to stop the generator for check 2 7 3 DC application DC terminals are used only for charging 12V battery At the time of using 12Vfor charge the air switch should be set at OFF state On the 12Voutput terminals a charge switch can be connected so the switch can be used for on...

Страница 14: ...2 8 1 Remove the load of the generator set 2 8 2 Turn off the air switch of the generator set 2 8 3 Set the speed handle of the engine to RUN position Carry out the unload operation of the diesel engine for 3 minutes Do not brake the diesel engine suddenly because this may make that the temperature goes up abnormally and cause the blocking up of the oil nozzle and the damage of the diesel engine P...

Страница 15: ...d bolts Chang lube oil 1st time 2nd and thereafter Clean oil filter replace if necessary Air cleaner element replacement Service more frequently when used in dusty areas replace Clean fuel filter replace Check fuel injection pump Check fuel injection nozzle Check fuel pipe replace if necessary Adjust valve clearance for intake and exhaust valves 1st time Lap intake and exhaust valves Replace pisto...

Страница 16: ...plug and drain the old oil while the engine is still warm The plug is located on the bottom of the cylinder block Tighten the drain plug and refill with recommended oil 3 1 2 Cleaning the oil filter Clean Every 6 months or 500 hours Replace Replace if necessary 3 1 3 Changing the air cleaner element Do not wash the air cleaner element with detergent because this is a wet type element Change Every ...

Страница 17: ...cal damage to the battery and also the electrolyte level and replenish with distilled water up to the upper mark if necessary when actual damage is discovered replace the battery Battery fluid check monthly 3 2 Maintenance for a long time storage If your generator should be storage in a long time the following preparation should be made 3 2 1 Operate the diesel engine about 3 minutes the stop it 3...

Страница 18: ... is not at RUN position Put the control level to RUN position Check the level of lubricant The specified oil level should be between upper level H and lower level L The speed and force to pull the recoil starter is not enough Start the diesel engine according to the requirements of operating procedure of start The oil nozzle has dirty Clean the nozzle The diesel engine can no start The battery has...

Страница 19: ...17 ...