ITC Audio T-6202 Скачать руководство пользователя страница 1

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.

SPEAKER SELECTOR

O

P

E

R

A

T

IO

N

 M

A

N

U

A

L

AUDIO

AUDIO

PUBLIC ADDRESS SYSTEM

T-6202

9

10

8

6

7

SPEAKER ZONES

5

3

4

T-6202

SPEAKER SELECTOR

2

1

POWER

ON

OFF

Содержание T-6202

Страница 1: ...ain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference SPEAKER SELECTOR OPERATION MANUAL AUDIO AUDIO PUBLIC ADDRESS SYSTEM T 6202 9 10 8 6 7 SPEAKER ZONES 5 3 4 T 6202 SPEAKER SELECTOR 2 1 POWER ON OFF ...

Страница 2: ...S T 6202 2 1 SAFETY PRECAUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 8 6 APPLICATIONS 9 7 SPECIFICATIONS 10 8 DIMENSIONAL DIAGRAM 11 MACHINE OPERATION ...

Страница 3: ...n fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstable ...

Страница 4: ...oty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on Lo...

Страница 5: ...one for background music programs the other for paging and emergency notification 2 GENERAL DESCRIPTION Generate EMC signal Built in siren and user recorded message Two minutes recording and output Recording signal and volume control Automatic or manual operation LED power indicator T 6202 ...

Страница 6: ...Power Press the end power shut down 4 NOMENCLATURE AND FUNCTIONS 2 3 3 SPEAKER ZONES 1 10 Zone activation switches 4 SPEAKER ZONES 1 10 Speaker zones 1 10 indicators 1 4 1 FRONT PANEL POWER T 6202 SPEAKER SELECTOR ON OFF 1 2 3 4 5 6 7 8 9 10 SPEAKER ZONES 4 T 6202 ...

Страница 7: ...0 ALARM IN A B Alarm signal input A B terminal 11 INPUT A B Amplifier input A B 5 4 2 REAR PANEL 7 6 RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO COM INPUT A INPUT B ALARM A ALARM B CH 1 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 2 1 2 3 4 5 6 7 8 9 10 ALARM IN 1 2 3 4 5 6 7 8 9 10 ALARM OUT 220V 50Hz T1AL250V 8 9 10 11 T 6202 ...

Страница 8: ...gnal due to pear A sit up input exigence broaddcast signal due to B sit up input as nothing exigence broadcast focus on sth amplifier can hold A B sit up parallel connection 2 Press at will subarea choose key be can choose be one s turn subarea 8 T 6202 ...

Страница 9: ... 350W 500W 650W T10AL250V T12AL250V RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO PAGING SELECTOR RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO COM INPUT A INPUT B ALARM A ALARM B CH 1 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 2 1 2 3 4 5 6 7 8 9 10 ALARM IN 1 2 3 4...

Страница 10: ... DIMENSIONS MM CONTROL PROTECTION POWER CONSUMPTION NET WEIGHT 484X368X88 500W MAX POWER INPUT 110 120V AC or 230 240V AC 50 60Hz 24V DC optional Individual zone selectors power switch AC fuse 1A 40W 5 7Kg 10 Power LED channel status LEDs BGM or Priority 4 5Kg 1500W speaker load GROSS WEIGHT A BGM B priority 100V or 70V COM T 6202 ...

Страница 11: ...ER ZONES RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO COM INPUT A INPUT B ALARM A ALARM B CH 1 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 2 1 2 3 4 5 6 7 8 9 10 ALARM IN 1 2 3 4 5 6 7 8 9 10 ALARM OUT 220V 50Hz T1AL250V POWER T 6202 SPEAKER SELECTOR ON OFF 1 2 3 4 5 6 7 8 9 10 SPEAKER ZONES T 6202 ...