Archimede 5000 series- FM Power Amplifiers
User’s manual – Page 16 of 65
5.2.a
REMOTE connector
The
REMOTE
connector [14] gathers mainly information about the equipment status (alarms status and internally carried measures).
The following table describes these I/O signals:
Pin
Signal
Description/Notes
1
-
(not connected)
2
High reflected power alarm
If this status is reached, the output on this pin is +12V
DC
.
3
-
(not connected)
4
Direct power measure
Range from 0 to 2V
DC
(full range).
5
Reflected power measure
Range from 0 to 2V
DC
(full range).
6
Low direct power alarm
If this status is reached, the output on this pin is +12V
DC
.
7
Not connected
(not connected)
8
DC power supply
External 12 V
DC
for service purposes (20mA Max)
9
-
(not connected)
10
Stand by
To set the equipment in stand by mode connect this pin to pin 8 or to an ex12V
DC
.
11
Power adjustment input command
Range from 0 to 4V
DC
(from 0W up to full output power).
12
Temperature alarm
If this status is reached, the output on this pin is +8V
DC
.
13
-
(not connected)
14
-
(not connected)
15
-
(not connected)
16
-
-
17
-
-
18
-
-
19
-
-
20
-
-
21
-
-
22
-
-
23
-
-
24
-
-
25
-
-
Содержание ARCHIMEDE 5000 Series
Страница 56: ...Archimede 5000 series FM amplifiers User s manual Page 56 of 65 Figure 5 Archimede 5000 Top view open ...
Страница 58: ...Archimede 5000 series FM amplifiers User s manual Page 58 of 65 Figure 7 Power Supply unit Circuit diagram 1 7 ...
Страница 59: ...Archimede 5000 series FM amplifiers User s manual Page 59 of 65 Figure 8 Power Supply unit Circuit diagram 2 7 ...
Страница 60: ...Archimede 5000 series FM amplifiers User s manual Page 60 of 65 Figure 9 Power Supply unit Circuit diagram 3 7 ...
Страница 65: ...User s manual Page 65 of 65 ...