Green Heating Technology
50
Hydraulic diagram
This diagram is for information only.
To make boiler hydraulic connection either see "Dimen-
sions and connections" on page 14 and eventually "Positioning and fastening" on page 16.
00080 00
M
M
8
55
56
51
32
54
17
18
23
22
14
10
34
11
20
16
21
30
24
31
27
13
15
58
57
52
28
29
19
C
F
R
M
SC
G
53
50
40
35
33
12
37
36
8
Sealed chamber
10
Gas injection pipe
11
Siphon for condense outlet
12
Temperature Sensor on system return
13
Loss of water pressure switch
14
Gas valve
15
System pressure gauge
16
Safety valve 3 bar
17
Filling valve
18
Drain valve
19
By-pass
20
Pump
21
Storage safety valve 8 bar
22
DHW filter
23
Flow limiter
24
Storage drain valve
27
Storage tank
28
Motorized 3-way valve
29
Automatic Venting Device
(heating circuit, incorporated in the pump)
30
DHW expansion vessel
31
Storage temperature sensor
32
Fan
33
Temperature Sensor, system flow
34
Air/Gas Mixing System
35
Safety thermostat on system flow
36
Manual venting valve (storage coil)
37
Heating system expansion vessel
40
Manual Venting Device (Combustion assembly)
50
Primary exchanger (condensing section)
51
Primary exchanger (combustion section)
52
Check valve
53
Flue hood
54
Condense drain in combustion assembly
55
Combustion chamber
56
Burner
57
Overflow drain of condensate trap
58
Tap for condensate trap cleaning
C
Hot water outlet
F
Cold water inlet
R
Heating return
M
Heating flow
SC
Condense drain
G
Gas inlet
Содержание CITY MAX 26 K
Страница 53: ...Green Heating Technology 53 Notes ...