Examples of installation of inlet and outlet ducts
We give you some correct and wrong examples of installation of inlet and outlet ducts for condensing
boilers (the slope are voluntarily represented in an exaggerated way).
A =
Inlet;
S =
Outlet.
1:
the most functional and economic solution is to let the condense come back towards the
boiler.
2-3:
if an obstacle prevents to install the ducts upwards, it is necessary to install condense collectors, so as to
avoid stagnations.
4:
the slope upwards of the inlet ducts, for their all length or at least only for the external tract, is
sufficient to prevent that the rain water reaches the combustion chamber.
5:
so the inlet must not be downwards.
6:
do not let the condense go out from the flue outlet terminal.
7:
the coaxial inlet/outlet duct must be installed so
as the flues are upwards, and so the condense discharge itself towards the boiler. The terminal tract with inlet head
and outside with an outlet out axis must be horizontal placed and it is equipped with ribs which prevents the water
entrance in the external inlet duct. The internal outlet duct is upwards and canalises the condense in the correct
direction.
1
2
3
S
S
A
A
A+S
A A
S
S
S
00045 00
4
5
7
6