Warnings for the installation of optional kits or special systems
Floor heating system
The safety thermostat(s) that protects the floor against overheating (that could damage the
cladding, the structure or the system itself) must be installed on the flow starting end of the
serpentine embedded in the floor itself. It should not installed on the system flow pipe in prox-
imity of the boiler, otherwise frequent and unjustified boiler locks, caused by its triggering, are
possible.
Specifications for inlet air
Air must be withdrawn from places free of pollutant (like fluorine, chlorine, sulfur, ammonia, alkaline or
similar agents). In the event of installation of the boiler in atmospheres with not negligible presence of
aggressive chemical substances (e.g. hairdressing salons, laundries) we recommend to foresee the air
inlet from outdoor, choosing the type C installation.
Domestic water supply characteristics
The cold water inlet pressure must be lower than 8 Bar
(higher pressure will lead to the storage safety
valve triggering). Besides, for an optimal boiler functioning, water pressure
should be more than 1 Bar
.
A lower pressure could make difficult to restore correctly the pressure of the heating system.
In case of higher pressure
it is indispensable to install a PRESSURE REDUCER
upstream the
boiler.
The cleaning frequency of the storage coil depends on the water supply hardness. If the water hard
-
ness is more than 25° fr it’s required to install a softener to bring the hardness below that value.
Besides, the presence of solid residuals or impurities in the water (for example in case of new systems)
could compromise the correct functioning of the boiler. For DHW production systems, the regulation in
force prescribes a safety filter to protect the systems.
The condensing burner/exchanger assembly requires particular characteristics for the heating
system liquid
, more restrictive than the ones of the inlet domestic water. See the "Heating" sec-
tion of the table "Technical data" on page 45.
Protection against freezing
Thanks to its antifreeze system, inner components could never reach a temperature lower than 5°C. This
system is activated when the boiler is supplied by the electrical and gas lines, provided that the pressure
in the heating system is correct.
In case of boiler installation in rooms where temperature can drop down to 0°, it is advisable
to fill the heating circuit (included the primary circuit of the storage unit and the relevant coil)
with an antifreeze liquid specific for heating systems, propylenic glycol based, following the in-
structions of its manufacturer. Pay attention to the correct product concentration: adding those
substances to the heating water in incorrect dose could lead to the deformation of the seals and
cause unusual noises during operation.
ITALTHERM S.r.l. will not be held responsible for consequent damages.
Instruct the User about the antifreeze function of the boiler and about the antifreeze product
added in the heating system.