background image

 

 

iSysmart 

 

ZigBee

TM

- Switch 

 

 

 

User Manual 

 

 

 

 

 

 

Wireless Touch Panel Switch with Power Meter (3-

Gang) Model: SGZ825C 

 

 

 

 

 

 

Firmware:

 

V1.1 

 

Hardware:

 

V1.0 and above 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
  

FW V2.1 (20150922) 

HW V1.0 

Содержание SGZ825C

Страница 1: ...1 1 iSysmart ZigBee TM Switch User Manual Wireless Touch Panel Switch with Power Meter 3 Gang Model SGZ825C Firmware V1 1 Hardware V1 0 and above FW V2 1 20150922 HW V1 0 ...

Страница 2: ...voltage power energy consumption monitoring feature It helps people manage and save the power spending much easier What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is defined for a general purpose cost effective low power consumption low dat...

Страница 3: ...3 3 iSysmart 2 Product Appearance Button 1 Indicator 1 Button 2 Indicator 2 Button 3 Indicator 3 Network Indicator Binding Key L Out 3 L Out 2 L Out 1 L In N In ...

Страница 4: ... Protection The current is over 8A it will be off load in 120 seconds The current is over 10A it will be off load in 60 seconds The current is over 12A it will be off load in 30 seconds The power consumption data is saved every 10 seconds 5 Setting up SGZ825C 5 1 Join the ZigBee Network After SGZ825C is turned on it will search for an existing ZigBee network and send a request to join the network ...

Страница 5: ...for 3 seconds The Network Indicator will flash cyan once Step2 Release the Binding Key and then short press the Binding Key N times EP1 L1 once EP2 L2 twice EP3 L3 three times within 5 seconds For example press the Binding Key 3 times when you would like to bind Button 3 Step3 Enable the binding feature of the On Off device Step4 The Network Indicator flashes cyan 5 times after the binding is comp...

Страница 6: ...ufacturer Transaction Command Frame payload control code Sequence identifer Action number 0x05 0x109F 0xe0 0x00 clusterid 0x0702 Action 0x00 5 6 Reset Power Consumption Summation To reset the power consumption data please follow the steps Step1 Press and hold the Binding Key for 20 seconds The Network Indicator will flash cyan 5 times at the 3rd 6 th 10 th 15 th and 20 th second Step2 After releas...

Страница 7: ... check if attribute Bit1 Current OverLoad level of ACAlarmsMask is 1 If it s 1 and then device will send Alarm If it s 0 and then device will not send Alarm When alarm is on AlarmCluster 0x0B04 AlarmCode 0xF0 network indicator flash 10 times 10 250 250 2 Power data saving chip AT2401 saving data every 30 seconds Power data saving chip AT2402 saving data every 10 seconds Power data saving chip AT24...

Страница 8: ...mperatures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the device and damage the device or battery Do not drop knock or shake the device Rough handling would break it Do not use strong chemicals or washing to clean the device Do not paint the device Paint wo...

Отзывы: