background image

i

Sysmart

 

 

 

 

ZigBee

TM

-Range Extender 

 

 

User Manual

 

 

 

User Manual 

Range Extender

 

 

Firmware:  V4.2 

Hardware:  V1.1

 

SGZ809C 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

20141118

 

Содержание SGZ809C

Страница 1: ...iSysmart ZigBeeTM Range Extender User Manual User Manual Range Extender Firmware V4 2 Hardware V1 1 SGZ809C 20141118 ...

Страница 2: ...GZ809C 4 5 1 Power on 4 5 2 Join the ZigBee Network 4 5 3 Permit Join 4 5 4 Identify 5 5 5 Restore to Factory Setting 5 5 6 Backup battery Disable Enable 5 5 7 Battery Voltage Report and Low Voltage warning 5 5 8 Backup Battery Recharge 6 6 Home Automation Clusters for SGZ809C 7 9 Important Maintenance Instructions 10 ...

Страница 3: ...ender SGZ809C is equipped with a battery backup power in time of power cut What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is defined for a general purpose cost effective low power consumption low data rate and easy to install wireless solu...

Страница 4: ...3 iSysmart Status Indicator Network Indicator Binding key 2 Product Appearance Figure SGZ809C different plug head is provided for different region ...

Страница 5: ...ork and send a request to join the network automatically While SGZ809C is under the coverage from a coordinator or a router whose permit join feature is enabled SGZ809C will be permitted to join the network A Before SGZ809C is joined a ZigBee network the network indicator will be off B After SGZ809C has joined a ZigBee network the network indicator stays on 5 3 Permit Join SGZ809C is designed to w...

Страница 6: ...ower from backup battery to function in the time of power outage event To disable backup battery Hold press binding key for 3 seconds until the indicator flashes once then release the key If successful the indicator would flash 10 times quickly To enable backup battery Hold press binding key for 3 seconds until the indicator flashes once then release the key If successful the indicator would flash...

Страница 7: ...or delete configuration information SGZ809C will stop detecting and reporting 5 8 Backup Battery Recharge After joining the network power detection will be on every 10 minutes Once battery power is less than 2 4V device will start to recharge for 16 hours In addition users can change value of ALARM MASK to be 1 to enable low voltage warning to be 0 to disable low voltage warning while recharging L...

Страница 8: ... 0003 Commission 0x0015 power configure 0x0001 Diagnostics Information 0x0B05 a Attributes of the Basic Device Information attribute set Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x2A O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read ...

Страница 9: ...onal 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x01 M 0x0010 LocationDescription Character string 0 17 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0 0x01 Read write 0x01 M ...

Страница 10: ...34 0 To report instantly To report per Maximum interval 0 To report per second To report per second 1 65534 0 0 To report per Minimum interval No report 0 To report per Minimum interval To report per Minimum interval 0 0 0 To report instantly No report 0 To report per second To report per second Any 65535 Any Stop reporting 65535 Any Any Stop reporting Note 1 It is not suggested to set Min Interva...

Страница 11: ...vice in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connectivity of the electron...

Отзывы: