IsoLux IsoLED PLUS Скачать руководство пользователя страница 1

 

IsoLux llc, 1045 Collier Center Way, Naples, Florida USA 34110 phone: 239 514 7475 fax: 239 514 7476 

email: 

[email protected] 

 web: 

www.isoluxllc.com

 

 

 

 
 
 
 
 

2.0   Operating Instructions 

2.1 Charging the Battery 

1.

 

Plug the charger

’s

 male connector into the 

receptacle on the Battery Pack.   

2.

 

Plug the AC connection into a 100-240 VAC 
source. 

3.

 

The charger indicator light will illuminate red 
while charging and turn green when charging is 
complete (approximately 3.6 hours). 

4.

 

An 85% partial charge may be performed in 2 
hours. 

5.

 

Disconnect the charger from the AC source and 
unplug the charger from the control unit. 

 

2.2 Illuminator and Headband Operation 

1.

 

Plug the Cable Assembly into the illuminator 
unit receptacle.  There are red orientation dots 
that must be aligned. 

2.

 

The cable should be routed and snapped into 
place through a set of two cable clips.  For dual 
ratchet headsets one is located on the top on 
the crown and one on the rear of the headband.  
The user has the choice of using the set on the 
left or the right. 

3.

 

For softband/Velcro  headsets, the cable should 
be routed through two clips along the 
circumference.   

4.

 

The illumination spot size may be adjusted by 
turning the grooved dial on the headlight. 

5.

 

The linkage assembly on the headband allows 
for personal positioning control. The joystick is 
used to further adjust the position of the light 
beam. 

 

2.3 Control Unit / Battery Pack Operation 

1.

 

Assure the Cable Assembly is plugged into the 
illuminator unit receptacle.  There are red 
orientation dots that must be aligned. 

2.

 

Plug the other end of the Cable Assembly into 
the Control Unit/ Battery Pack receptacle, once 
again aligning the red dots. 

3.

 

Clip the control unit where desired or place in a 
pocket. 

4.

 

Turn the ON/OFF and intensity control knob 
clockwise to turn unit On (switch will close).  
This knob also controls the intensity. 

5.

 

To turn unit Off, turn control knob counter-
clockwise until switch opens.   

6.

 

When battery has discharged to a level too low 
to maintain operation, the Illuminator will dim 

IsoLED Plus 

HEADLIGHT 

User’s Guide

 

1.0

 

Purpose and Features of the product 

1.1

 

Purpose 

The headlight is used for examination, diagnostics 
and surgical operations for multifarious uses 
including microsurgery.  

1.2   Features 

 

50,000 hours of LED life provides for a 
maintenance free device with an end life of 
approximately 20 years. 

 

The unit has infinite mobility, not confined by 
access to power sockets, and its charge will last 
more than 3 1/2  hours at full intensity. 

 

Its light beam is extremely homogeneous and 
free of imperfections. 

 

 Its high CRI rating of 96 is very desirable in 
color-critical applications such as neonatal care, 
medicine and surgery, as it shows the true 
colors of tissues and skin, thereby reducing the 
time to diagnosis and surgery. 

 

The light-weight battery packs have a retention 

clip to be used on the user’s belt or pocket. 

 

 

The wall mounted Battery Charger comes with a 
Charge Monitor that alerts the operator when 
the Battery is fully charged. 

 

The unit comes with two (2) Battery Packs, 

allowing for “Hot Swap” and the extension of its 

operating time to > 7 hours. 

 