2  Safety Rules

Improper wiring of the product can damage it and lead to other hazards. Make sure 

that the product has been correctly wired before turning the power on.

Before  wiring  or  removing/mounting  the  product,  make  sure  to  turn  the  power  off. 

Failure to do so might cause an electric shock.

Do not touch electrically charged parts such as power terminals. Doing so might cause 

an electric shock.

Do  not  disassemble  the  product.  Doing  so  might  cause  an  electric  shock  or  faulty 

operation.

Use the product only within the operating ranges recommended in the specification 

(temperature, humidity, voltage, shock, mounting direction, atmosphere, etc.). Failure 

to do so might cause a fire or faulty operation.

Firmly tighten the wires to the terminal. Failure to do so might cause a fire.

Avoid  installing  the  product  in  close  proximity  to  high-power  electrical  devices  and 

cables, inductive loads, and switching devices. Proximity of such objects may cause an 

uncontrolled interference, resulting in an instable operation of the product.

Proper arrangement of the power and signal cabling affects the operation of the entire 

control system. Avoid laying the power and signal wiring in parallel cable trays. It can 

cause interferences in monitored and control signals.

It  is  recommended  to  power  controllers/modules  with  AC/DC  power  suppliers.  They 

provide better and more stable insulation for devices compared to AC/AC transformer 

systems, which transmit disturbances and transient phenomena like surges and bursts 

to  devices.  They  also  isolate  products  from  inductive  phenomena  from  other 

transformers and loads.

Power supply systems for the product should be protected by external devices limiting 

overvoltage and effects of lightning discharges.

Avoid  powering  the  product  and  its  controlled/monitored  devices,  especially  high 

power and inductive loads, from a single power source. Powering devices from a single 

power source causes a risk of introducing disturbances from the loads to the control 

devices.

If an AC/AC transformer is used to supply control devices, it is strongly recommended 

to use a maximum 100 VA Class 2 transformer to avoid unwanted inductive effects, 

which are dangerous for devices.

Long  monitoring  and  control  lines  may  cause  loops  in  connection  with  the  shared 

power  supply,  causing  disturbances  in  the  operation  of  devices,  including  external 

communication. It is recommended to use galvanic separators.

To  protect  signal  and  communication  lines  against  external  electromagnetic 

interferences, use properly grounded shielded cables and ferrite beads.

Switching the digital output relays of large (exceeding specification) inductive loads can 

cause interference pulses to the electronics installed inside the product. Therefore, it 

is recommended to use external relays/contactors, etc. to switch such loads. The use 

of controllers with triac outputs also limits similar overvoltage phenomena.

Many  cases  of  disturbances  and  overvoltage  in  control  systems  are  generated  by 

switched, inductive loads supplied by alternating mains voltage (AC 120/230 V). If they 

do  not  have  appropriate  built-in  noise  reduction  circuits,  it  is  recommended  to  use 

external circuits such as snubbers, varistors, or protection diodes to limit these effects.

Содержание SfAR-1M-4DI

Страница 1: ...www ismacontrolli com DMP269en 3rd Issue rev 1 05 2022 SfAR 1M 4DI User Manual Expansion Module 4 Digital Inputs ...

Страница 2: ...cation 7 4 1 Grounding and Shielding 7 4 2 Network Termination 7 4 3 Types of Modbus Functions 7 4 4 Communication Settings 8 4 4 1 Default Settings 8 4 5 Configuration Registers 8 5 Indicators 10 6 Connections 11 6 1 Block Diagram 11 6 2 Power Supply Connection 11 6 2 1 DC Power Connection 11 6 2 2 AC Power Connection 12 6 3 Communication Bus Connection 12 6 4 Connection of Digital Inputs 12 7 Mo...

Страница 3: ...f the product without incurring any liability for the purposes of commercial law This information does not discharge you from the liability of your own judgement and verification We reserve the right to change product specifications without notice Please read the instructions carefully and follow the recommendations concluded therein 1 1 Revision History Rev Date Description 3 1 25 May 2022 Rebran...

Страница 4: ...enomena like surges and bursts to devices They also isolate products from inductive phenomena from other transformers and loads Power supply systems for the product should be protected by external devices limiting overvoltage and effects of lightning discharges Avoid powering the product and its controlled monitored devices especially high power and inductive loads from a single power source Power...

Страница 5: ...rovides fast processing and quick communication The baud rate is configurable from 2400 to 115200 The module is designed for mounting on a DIN rail in accordance with DIN EN 5002 The module is equipped with a set of LEDs to indicate the status of inputs and outputs which is useful for diagnostic purposes and helping to find errors Module configuration is done via USB by using a dedicated computer ...

Страница 6: ...ower supply 3 pin Communication 3 pin Inputs 2 x 3 pin Configuration mini USB Size Height 90 mm Length 56 4 mm Width 17 5 mm Interface RS485 Up to 128 devices Table 2 Technical specification 3 3 Dimensions The appearance and dimensions of the module are shown below The module is mounted directly to the rail in the DIN industry standard Figure 1 Dimensions ...

Страница 7: ...signals cable shields should not be interrupted by intermediate terminals the shielding should be earthed directly after the cable enters the cabinet It is recommended to install interference suppressors when switching inductive loads e g coils of contactors relays solenoid valves RC snubbers or varistors are suitable for AC voltage and freewheeling diodes for DC voltage loads The suppressing elem...

Страница 8: ...in the 16 bit registers The access to registers is via Modbus RTU or Modbus ASCII 4 4 1 Default Settings Parameter Name Value Address 1 Baud rate 19200 Parity No Data bits 8 Stop bits 1 Reply delay ms 0 Modbus type RTU Table 4 Default settings 4 5 Configuration Registers Modbus Address Decimal Address Hex Address Name Values 40003 2 0x02 Baud Rate 0 2400 1 4800 2 9600 3 19200 4 38400 5 57600 6 115...

Страница 9: ...n 3rd Issue rev 1 05 2022 page 9 of 16 Modbus Address Decimal Address Hex Address Name Values 40004 3 0x03 Data Bits 7 7 data bits 8 8 data bits 40006 5 0x05 Response Delay Time in ms 40007 6 0x06 Modbus Mode 0 RTU 1 ASCII Table 5 Configuration registers ...

Страница 10: ...6 5 Indicators Figure 2 Indicators Indicator Description ON The LED indicates that the module is correctly powered TX The LED lights up when the unit received the correct packet and sends the answer DI1 2 3 4 The LED indicates that on the input is high state Table 6 Description of indicators ...

Страница 11: ...er Manual www ismacontrolli com DMP269en 3rd Issue rev 1 05 2022 page 11 of 16 6 Connections 6 1 Block Diagram Figure 3 Block diagram 6 2 Power Supply Connection 6 2 1 DC Power Connection Figure 4 DC power connection ...

Страница 12: ...m DMP269en 3rd Issue rev 1 05 2022 page 12 of 16 6 2 2 AC Power Connection Figure 5 AC power connection 6 3 Communication Bus Connection Figure 6 Communication bus connection 6 4 Connection of Digital Inputs Figure 7 Connection of digital inputs ...

Страница 13: ...ode ASCII or RTU 40009 8 0x08 Watchdog Read write Watchdog 40033 32 0x20 Received Packets LSR Least Significant Register Read write No of received packets 40034 33 0x21 Received Packets MSR Most Significant Register Read write 40035 34 0x22 Incorrect Packets LSR Read write No of received packets with error 40036 35 0x23 Incorrect Packets MSR Read write 40037 36 0x24 Sent Packets LSR Read write No ...

Страница 14: ...0067 66 0x42 CCounter 4 LSR Read write 32 bit value of captured counter 4 40068 67 0x43 CCounter 4 MSR Read write 40069 68 0x44 Counter Config 1 Read write Counter configuration 1 time measurement if 0 counting impulses 2 autocatch counter every 1 sec 4 catch value when input low 8 reset counter after catch 16 reset counter if input low 32 encoder 40070 69 0x45 Counter Config 2 Read write 40071 70...

Страница 15: ...ounter 1 1154 1153 0x481 Capture 2 Read write Capture counter 2 1155 1154 0x482 Capture 3 Read write Capture counter 3 1156 1155 0x483 Capture 4 Read write Capture counter 4 1169 1168 0x490 Captured 1 Read write Captured value of counter 1 1170 1169 0x491 Captured 2 Read write Captured value of counter 2 1171 1170 0x492 Captured 3 Read write Captured value of counter 3 1172 1171 0x493 Captured 4 R...

Страница 16: ...s network as well as to read and write the current value of other registers of the module It is a convenient way to test the system as well as to observe real time changes in the registers Communication with the module is via the USB cable The module does not require any drivers Figure 8 PC connection The SfAR Configurator is a universal software where it is possible to configure all available mod...

Отзывы: