Non contractual document. Subject to change. Cod. 60000STY2LV01.3 - 08/05/2018

Stylos 2 Credential Reader inst. guide (UK) - © 2017  Iseo Serrature S.p.a. - www.iseo.com

INSTALLATION GUIDE (UK)

WARNINGS

Read this manual prior to use the device in order to ensure a safe and proper use.

Preserve this manual as future reference.

The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.

The instructions should be carefully followed during installation. These instructions and any maintenance 
instructions should be passed on by the installer to the user.

No modifications of any kind are permitted, except for those described in these instructions.

The product must be destined only for the use for which it is expressly designed and therefore as a 
credential reader for civil and industrial locations. Any other use is considered improper and dangerous.

The electrical connection must be made according to the constructor's instructions and respecting the
regulations in force.

In the event of a failure and/or poor operation, remove the power supply using the main switch and do not

tamper with it. For all repairs, exclusively contact a technical assistance center authorized by the constructor.

Before performing any cleaning operation on the product, uncouple the appliance from the electrical power

supply network, by opening the system switch.

2. DISASSEMBLING

3

1

4

2

Disconnect the power before opening the device.

3. 

STAND-ALONE GATE

 SETTING

Back side view

Circuit board

Only to set the Stylos 2 to be used as 

Stand-Alone 

gate

, you have to close, by a jumper, PIN 2 and 3 as 

shown in the picture.

Fit the jumper when
the Stylos is OFF.

1. VERSIONS AND DIMENSIONS

A = 47,5mm
B = 17,5mm
C = 130mm

A = 40mm
B = 10mm
C = 125mm

C

A

B

Credential reader

with led

Spacer for wall

installation

JP 1

Back side view

Circuit board

J2.

1

J2.

2

J2.

3

J2.

4

1.2.3

JP2

S1

ADDRESS  5 =

ADDRESS  6 =

ADDRESS  7 =

ADDRESS  8 =

ADDRESS  1 =

ADDRESS  2 =

ADDRESS  3 =

ADDRESS  4 =

BUS
ADDRESS

(Communication Channel)

NEGATIVE (-) GND

POSITIVE (+) Power Supply

LOCKBUS

}

BUS

ADDRESS

JP 1

J2.

1

J2.

2

J2.

3

J2.

4

1.2.3

JP2

S1

JP 1

4.1 

READER/VALIDATOR

 ELECTRICAL CONNECTIONS

mm²

0.20÷1.5 

Minimum/maximum cross-section

of the cables is:

(24÷15AWG).

    Power supply: 8÷30 VDC 0.5A 

MAX

This guide includes instruction 
to configure the Stylos as 

Stand-Alone gate

 or as 

Reader/Validator

, connected 

to Atlas. Refer to the proper 
section.

JP

6

JP

4

JP

2

JP

0

J2.

1

J2.

2

J2.

3

J2.

4

JPS

S1

1
2
3
4
5

Stylos as 

Stand-Alone gate

 = Address 0 (Master)

LEGEND:

J2.1/2/3/4 = Power supply/Lockbus
JPS = System Jumper (reserved)
S1 = Programming button
JP 0/2/4/6 = Bus Address Jumpers

JP

6

JP

4

JP

2

JP

0

Back side view

Circuit board

J2.

1

J2.

2

J2.

3

J2.

4

JPS

S1

ADDRESS  0 =

ADDRESS  2 =

ADDRESS  4 =

ADDRESS  6 =

BUS
ADDRESS

(Master)

(slave)

(slave)

(slave)

FUNCTION

(Communication Channel)

NEGATIVE (-) GND

POSITIVE (+) Power Supply

LOCKBUS

}

BUS

ADDRESS

JP

4

JP

2

JP

0

JP

6

J2.

1

J2.

2

J2.

3

J2.

4

JP

6

JPS

S1

JP

4

JP

2

JP

0

3.1 

STAND-ALONE GATE

 ELECTRICAL CONNECTIONS

mm²

0.20÷1.5 

Minimum/maximum cross-section

of the cables is:

(24÷15AWG).

    Power supply: 8÷30 VDC 0.5A 

MAX

 4.  

READER/VALIDATOR 

SETTING

For more information about Stylos and Atlas, refer to 
the 

Atlas Installation Manual 

available at:

http://gamma.iseozero1.com/en/controllo-accessi/

JP

6

JP

4

JP

2

JP

0

Back side view

Circuit board 

J2.

1

J2.

2

J2.

3

J2.

4

JPS

S1

Stylos as 

Reader/Validator

 = Address 1