Interferences
Defect
Cause
Solution
System can not be switched on
Mains connection is not available
Check circuit
Plug in AC power connector
Main switch not switched on
Switch on main switch
POWER push-button does not work
Cover not closed
Close cover
Emergency stop not unlatched
Unlatch Emergency stop
Driving motor does not react
No voltage supply of the
Check fuse in power block
power stage, fuse is defective
Check fuse in power output stage
Temperature protection of the
Check fan in the controller
power stage is active
Check slots in the bottom plate
(LED Temp lights)
Power stage is defective
Change power stage (send in)
Connector has loosened
Check connector at the controller
output and at the motor
Cable break
Replace cable
Processing machine (spindle)
Not enabled by the software
Enable via software does not work
Rotary switch at that machine is
Switch on the machine
off (Kress)
False driver installed
Use matching driver
Machine is in home position
Move machine into work-space
Cover bolting device is open
Close cover bolting device with the
three edge key
Safety device in the converter
AC power connectors draw
is defective
Refresh safety device