8.5. Channel Control
Access:
read-write
Data-Type:
UI4
Command:
:READ:CHAN
nel
:CONT
rol
?
:VOLT
age
˽
{ ON | OFF | EMCY OFF | EMCY CLR }
Bit31
Bit30
Bit29
Bit28
Bit27
Bit26
Bit25
Bit24
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Bit23
Bit22
Bit21
Bit20
Bit19
Bit18
Bit17
Bit16
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Bit15
Bit14
Bit13
Bit12
Bit11
Bit10
Bit09
Bit08
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Bit07
Bit06
Bit05
Bit04
Bit03
Bit02
Bit01
Bit00
Reserved
Reserved
Set Emer-
gency Off
Reserved
Set On
Reserved
Reserved
Reserved
The Channel Control register contains the control information of the channel.
There is no direct write access to this register by SCPI, instead the commands :VOLT ON/OFF and :VOLT:EMCY OFF/CLR are used
˽
˽
to control the channel.
Control Bit
Description
Set On
1 if the channel is set on by :VOLT ON or 0 if the channel is off.
˽
Set Emergency Off
1 if the channel is set to emergency off by :VOLT:EMCY OFF or 0 otherwise
˽
SCPI protocol common instruction set | Last changed on: 2020-11-10 |
www.iseg-hv.com
52/63