3.2. Ethernet
The Ethernet interface can be used to send SCPI commands through raw TCP sockets. On device side, the TCP port 10001 is used.
3.2.1 Hardware Implementations
Depending on the device, different Ethernet implementations are utilized. Though the hardware is different, all devices follow the
same programming model.
Device
Ethernet implementation
SHR
Standard Ethernet hardware and software-Implementation based on Linux network stack
HPS ≥ 1.5 kW
Lantronix XPort Ethernet hardware with serial protocol based software stack in the
microcontroller
HPS compact
FPS
MICC
HPS 300/800 W
Vendor specific Ethernet hardware and software stack in the microcontroller
Table 7: Ethernet hardware implementations
3.2.2 Connecting over Ethernet
The device can be connected directly to a switch with a patch cable. If it shall be connected to a PC directly (without switch), a
crossover cable has to be used.
The connection to the device can be tested with the ping command (Start
➜
Programs
➜
Accessories
➜
Command):
C : \ >p i n g 1 9 2 . 1 6 8 . 1 6 . 2 2 1
P i n g wi l l d o n e f o r 1 9 2 . 1 6 8 . 1 6 . 2 2 1 wi t h 3 2 by t e s d a t a :
A n s we r f r o m 1 9 2 . 1 6 8 . 1 6 . 2 2 1 : b y t e s =3 2 t i m e =4 m s T T L =1 2 8
A n s we r f r o m 1 9 2 . 1 6 8 . 1 6 . 2 2 1 : b y t e s =3 2 t i m e =4 m s T T L =1 2 8
A n s we r f r o m 1 9 2 . 1 6 8 . 1 6 . 2 2 1 : b y t e s =3 2 t i m e =4 m s T T L =1 2 8
A n s we r f r o m 1 9 2 . 1 6 8 . 1 6 . 2 2 1 : b y t e s =3 2 t i m e =4 m s T T L =1 2 8
P i n g s t a t i s t i c f o r 1 9 2 . 1 6 8 . 1 6 . 2 2 1 :
P a c k a g e : s e n t = 4 , r e c e i v e d = 4 , l o s t = 0
T i m e in m i l l i s e c o n d :
m i n i m u m = 1 m s , m a x i m u m = 4 m s , a v e ra g e = 1 m s
The factory IP settings are given in the following table:
The factory IP settings
IP address
HPS 300/800 W
192.168.16.13
All other devices
192.168.16.221
Netmask
255.255.255.0
Default gateway
192.168.16.1
Command TCP port
10001 (fixed)
Table 8: Factory IP settings
SCPI protocol common instruction set | Last changed on: 2020-11-10 |
www.iseg-hv.com