16-channel High Voltage Bipolar Power Supply EBS F 030 

 

V

O

 = - 3 kV  to + 3 kV / 500 µA 

 
 

 

Operators Manual 

 

(Device with SN: 77xxx) 

 
 

Contents 

 
 

1. General information 

 

2. Technical data 

 

3. Handling 

 

Certificate of calibration 

 

 

 

 

 
 
 
 

Attention! 

 

-It is forbidden to use the unit if the covers have been removed. 
 
-We decline all responsibility for damages and injuries caused by an improper use of the 

module. It is highly recommended to read the manual before any kind of operation. 

 
 
 

Note 

 

The information in this manual is subject to change without notice. We take no responsibility for any error in the 
document. We reserve the right to make changes in the product design without reservation and without 
notification to the users. 
 
Filename EBSF030_V100eng.___; version 1.00 as of 2009-05-05

Содержание EBS F 030

Страница 1: ... Certificate of calibration Attention It is forbidden to use the unit if the covers have been removed We decline all responsibility for damages and injuries caused by an improper use of the module It is highly recommended to read the manual before any kind of operation Note The information in this manual is subject to change without notice We take no responsibility for any error in the document We...

Страница 2: ... 3000 V voltage difference between the channels of one board must be less or equal than 3000 V Ripple and noise f 10 Hz to 100 MHz typ 10 mV max 50 mV under all load conditions Hardware current trip Potentiometer IImaxI for 16 channels Hardware voltage limit Potentiometer IVmaxI for 16 channels Interface CAN interface potential free Data format floating point single precision setting and measureme...

Страница 3: ... a current of any polarity is flowing in a range of 5 to 20 mA i e safety loop closed If the safety loop is opened during operation then the output voltages on all channels are shut off without ramp and the corresponding bit in the Status module will be cancelled After the loop will be closed again the channels must be switched ON and a new set voltage must be given before it is able to offer an o...

Страница 4: ...v de Phone 49 0 351 26 996 0 Bautzner Landstr 23 http www iseg hv com Fax 49 0 351 26 996 21 D 01454 Radeberg Rossendorf Germany 4 Pin assignment Multipin Redel HV connector 5 C RTN C RTN 8 9 10 15 14 2 1 C RTN 3 4 13 11 7 6 12 0 C RTN SL PIN 22 SL PIN 30 CCG CCG CCG CCG ...

Отзывы: