3.10.10
KNX communication objects
LVLØ controller is cyclically sending water condition values to the bus so these can be used in KNX
visualization. Water treatment hardware can be also monitored via KNX. It is possible to:
Display actual pH, Redox or free chlorine values.
Monitor conditions of water in pool and alert in case of issues with pH and redox parameters.
Monitor chemical stock alerts.
Monitor sensors status and alert in case of damaged or problematic probes, etc.
Monitor next service intervals for installed probes.
Change interval for cyclical sending of actual water condition communication object to KNX bus.
Group
Address
Data Point Name
Data Point Type
Description
10/0/12
LVLØ Current Actual pH Output
display of
value EIS5
2 Byte
R
9.*
Display actual pH value.
Floating value is sent to bus on change or cyclically based on
parameter 10/2/15.
10/0/13
LVLØ Current Actual Redox Output mV
display of
value EIS5
2 Byte
R
9.020
Display actual Redox/ORP value in mV (-2000 +2000).
Value is sent to bus on change or cyclically based on parameter
10/2/15.
10/0/14
LVLØ Current Actual Free Chlorine Output mg/l
display of
value EIS5
2 Byte
R
9.*
Display actual CLF (Free chlorine) value in mg/l (ppm).
Floating value is sent to bus on change or cyclically based on
parameter 10/2/15.
10/1/3
LVLØ Water Treatment Status Feedback
display of
value EIS5
2 Byte
R
7.*
Summarized status feedback object to display exact service code in
case of water treatment issues. Telegram with code is sent to bus
cyclically every 600s. Code explanation:
1 - pH (OK/ERR)
2 - ORP/CLF (OK/ERR)
4 - chemical stocks (OK/ERR)
8 - electrodes (OK/ERR)
10/1/9
LVLØ Sensors Status Feedback
display of
value EIS5
2 Byte
R
8.*
Summarized status feedback object to display sensors status
feedback messages. Telegram with code is sent to bus cyclically
every 600s. Code explanation:
1 - water temperature sensor (OK/ERR)
2 - outside temperature sensor (OK/ERR)
4 - ext. system temperature sensor (OK/ERR)
8 - pH electrode (OK/ERR)
16 - ORP electrode (OK/ERR)
10/1/11
LVLØ pH Electrode Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on pH electrode (calibration,
replacement), set via LVLØ mobile app.
Telegram with value is sent to bus cyclically every 600s.
10/1/12
LVLØ Redox Electrode Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on Redox electrode (calibration,
replacement), set via LVLØ mobile app.
Telegram with value is sent to bus cyclically every 600s.
10/1/13
LVLØ CLF Electrode Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on Free chlorine electrode
(calibration, replacement), set via LVLØ mobile app.
Telegram with value is sent to bus cyclically every 600s.
10/2/15
LVLØ Minimum Sensors Sending Interval Input (s)
control of
value EIS5
2 Byte
W
7.005
Control interval for sending measured values (temperatures, CLF,
pH, ORP) to bus. Applies only to sensors.
NOTE:
Details are documented in “KNX bus communication” in section 6.
For examples of KNX communication see section 6.4.
3.11
Backwash valve
3.11.1
Overview
Regular and correct backwash process of pool filter system is vital for ensuring crystal clear water. To always
get flawless results, LVLØ can directly control the backwash process in swimming pool. You can choose
between multi-port (6-way valve) and push-pull valve (e.g. Besgo). Possible 6-way valve positions are:
Filter - runs pool water from pump through the sand filter and back into the pool. This position is used most
of the time.