5.8 Removing SD Card
Step 1: Uninstall the SD card cover by removing the screws.
Step 2: Remove the SD card from the slot.
6. Electrical Wiring
Raptor
supports dual redundant hot swappable power supplies—Power Supply 1 (PWR1) and Power Supply 2 (PWR2). The
connections for PWR1 and PWR2 are located on the terminal block.
Electrocution hazard – risk of death, serious personal injury and/or damage to the device.
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a 24 or 48
power supply terminal block. Damage to the power supply may occur.
Caution – Access to wiring terminals and replaceable modules is restricted to Skilled Person only.
Multiple power source – redundant power. Disconnect all power sources.
6.1 Power Inputs and Fault Relay
The relay contact of the terminal block connector is used to detect user-configured events. The switch provides fail open
and fail close contacts to form relay circuits based on requirements. If the device is not powered, or if an active alarm is
present, the relay de-energizes, therefore initiating the NO and NC states.
The contacts are energized upon power up of the unit and remain energized unless a critical error occurs. One common
application for this output is to raise an alarm if a power failure or removal of control power occurs.