Label
Description
Enable Loop
Protection
Controls whether loop protections is enabled (as a whole).
Transmission
Time
The interval between each loop protection PDU sent to each port. The value must be
between 1 to 10 seconds.
Shutdown
Time
The period (in seconds) for which a port will be kept disabled when a loop is detected
(shutting down the port). The valid value is 0 to 604800 seconds (7 days). A value of
zero will keep a port disabled permanently (until the device is restarted).
Figure 48 - Port Configuration
Label
Description
Port
The switch port number of the port.
Enable
Controls whether loop protection is enabled on this switch port.
Action
Configures the action to take when a loop is detected. Valid values are
Shutdown
Port, Shutdown Port and
Log, or Log Only
Tx Mode
Controls whether the port is actively generating loop protection PDUs or only
passively looking for looped PDUs.
Save
Click to save changes
Reset
Click to undo any changes made locally and revert to previously saved values
Redundancy
iRing
iRing is the most powerful Ring in the world. The recovery time of iRing is less than 20 ms. iRing supports
3 topologies: iRing, Binding Ring and Dual Homing.