INSTALLATION

 

 

Pre-installation: 

 

Handling: 

 
This equipment may contain or be connected to static sensitive devices and proper static free handling precautions 
should be observed. 
 
Where  individual  circuit  cards  are  stored,  they  should  be  placed  in  antistatic  bags.  Proper  antistatic  procedures 
should be followed when inserting or removing cards from these bags. 
 

Power: 

 
AC mains supply:  

Ensure that operating voltage of  unit and local supply voltage match and that correct rating 
fuse is installed for local supply. 

 
DC supply:  

Ensure that the correct polarity is observed and that DC supply voltage is maintained within 
the operating range specified. 

 

Earthing: 

 
The earth path is dependent on the type of frame selected. In every case particular care should be taken to ensure 
that the frame is connected to earth for safety reasons. See frame manual for details. 
 

Signal earth: 

For safety reasons a connection is made between signal earth and chassis earth. 

 

No attempt should be made to break this connection. 

 

Installation in frame or chassis: 

 
See details in separate manual for selected frame type. 
 

Signal Inputs & Outputs:

 

 

For use with supplied standard rear assembly (ZDA-4010) or optional relay bypass rear assembly (ZDA-4010RL). 
 
The DDA-4010 can be configured as a single 1 IN, 8 OUT distribution amplifier, or as a dual 1 IN, 4 OUT distribution 
amplifiers  as  described  in  the 

Configuration

  section  of  this  handbook.  If  set  up  for  a  1  IN,  8  OUT  distribution 

amplifier,  either  input  can  be  configured  as  the  primary  input.  The  other  input  is  not  used  except  when  the 
automatic  changeover  function  is  enabled,  in  which  case  this  becomes  the  secondary  input.  See  the 

Operation

 

section of this manual for a complete description. 
 
Inputs, Outputs and front panel monitoring ports are 75 Ω BNC type for connection with high quality 75 Ω coaxial 
cable. Inputs are self-terminating. 
 
An  optional  relay  bypass  rear  assembly  (ZDA-4010RL)  is  available  where  the  inputs  are  outputted  to  one  of  the 
respective outputs (OUT 1A for Input A, and OUT 1B for Input B) on loss of power or removal of the card from the 
rear assembly itself. The bypass relay is suitable for all specified signals up to 3G-SDI. Note however that the cable 
equalisation at the 3G/HD-SDI rates and the return loss at the 3G-SDI rates are reduced through these relays. Note 
also that if operating in the 1x8 mode, if anything is connected to the secondary input this too will be switched to 
one of the outputs on loss of power or removal of card. 
 

Содержание DDA-4010

Страница 1: ...DDA 4010 IRT Electronics Pty Ltd www irtelectronics com Page 1 of 21 Revision 01 Single 1 In 8 Out Dual 1 In 4 Out 3G HD SD ASI Reclocking Non Reclocking Distribution Amplifier User Manual...

Страница 2: ...By Change Description Applicable to 00 03 01 2013 AL Original Issue Issue 3 PCB units fitted with firmware version 2 1 01 03 06 2013 AL DIP switch designators changed to SW1 and SW2 links LK1 and LK2...

Страница 3: ...arm Outputs 11 Front and Rear Layouts 12 Operation 13 Single 1 In 8 Out Mode 13 ChAx8 Input A to all 8 Outputs 13 ChBx8 Input B to all 8 Outputs 13 Automatic Changeover Mode 13 Non Reclocking Mode 14...

Страница 4: ...itions dangerous potentials may exist in some circuits when power controls are in the OFF position Maintenance personnel should observe all safety regulations Do not make any adjustments inside equipm...

Страница 5: ...present and whether the outputs are locked to the inputs An optional relay bypass rear assembly is available to switch the Inputs to one of their respective Outputs in the event of a power failure Si...

Страница 6: ...HD LED green x2 when HD SDI signal present and locked to selected input on either A or B outputs 3G LED green x2 when 3G SDI signal present and locked to selected input on either A or B outputs Alarm...

Страница 7: ...SW2 2 Auto Detect 3G HD SD ASI rates OFF OFF SD SDI ASI only ON OFF HD SDI only OFF ON 3G SDI only ON ON SW2 3 OFF I P B Reclocking mode DA behaves as a Reclocking DA ON I P B Non Reclocking mode Recl...

Страница 8: ...puts if desired ChBx8 Input B to all 8 Outputs 4 x Output A and 4 x Output B Sw1 5 OFF Single 1 In 8 Out DA mode Sw2 5 ON Input B primary input Data Rate For automatic detection of signal type so that...

Страница 9: ...ing Mode Sw1 3 OFF Input A reclocked A input behaves as a reclocking DA Sw2 3 OFF Input B reclocked B input behaves as a reclocking DA Non Reclocking Mode Sw1 3 ON Input A non reclocked A input behave...

Страница 10: ...nputs Outputs For use with supplied standard rear assembly ZDA 4010 or optional relay bypass rear assembly ZDA 4010RL The DDA 4010 can be configured as a single 1 IN 8 OUT distribution amplifier or as...

Страница 11: ...hBx8 mode alarm A is non functional regardless of input A s status unless automatic changeover mode is also set If in the dual ChAx4 ChBx4 mode both alarms A and B are functional regardless of whether...

Страница 12: ...DDA 4010 IRT Electronics Pty Ltd www irtelectronics com Page 12 of 21 Revision 01 Front rear panel connector diagrams ZDA 4010 Standard Rear Assembly ZDA 4010RL 3G HD SD ASI Relay Bypass Rear Assembly...

Страница 13: ...t data rate signal such as HD SDI Unless Automatic Changeover mode has been implemented even if a signal has been applied to the IN A port INPUT A will not illuminate See Automatic Changeover descript...

Страница 14: ...ode if an input signal is present the corresponding front panel INPUT LED will illuminate but the 3G HD and SD LEDs will not except in the case where the input data rate actually corresponds to a 3G H...

Страница 15: ...data rate the corresponding input and detected data rate LEDs will flash and the corresponding outputs will be muted unless the Automatic Changeover function has been implemented see Automatic Change...

Страница 16: ...nd B has been set for the SD SDI only rate Input A is being fed by a signal at the SD rate which is being fed to B s outputs as indicated by the INPUT A LED not flashing whilst A s SD data rate LED is...

Страница 17: ...ion and translates that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control comman...

Страница 18: ...that are SNMP compatible may need an optional plug in SNMP module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters su...

Страница 19: ...x4 Dual 1x4 DA IN A OUT 1A to OUT 4A IN B OUT 1B to OUT 4B 2 chAx8 Single1x8DA INAprimaryinput INA OUT1AtoOUT4A OUT1BtoOUT4B 3 chBx8 Single1x8DA INBprimaryinput INB OUT1BtoOUT4B OUT1AtoOUT4A autoChang...

Страница 20: ...Reclocker enable bypass option is not applicable to the secondary input of a single 1x8 DA mode If the user sets this parameter to na the reclocker will default to the enabled setting alias A 16 chara...

Страница 21: ...re Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be servic...

Отзывы: