WIRING 

Alex-Tronix 

Controls 

FILTER  BACKWASH  CONTROLLERS 

F3 AC/DC/DCL INSTRUCTIONS 

OWNER'S  MANUAL 

The standard F3AC comes with the 115 VAC transformer. For 230 Volt input, replace the 115 VAC transformer with the optional 230 

VAC transformer.  230 VAC transformers are marked "230".  The output can be selected to operate either 24 VAC or 12 VDC 

solenoids when the input power is AC. If the input power is either 12 VDC from a battery, diesel generator battery or by solar panel, 

the output is selectable to operate either regular 12 VDC solenoids or two wire latching solenoids for solar applications. The output 

terminal wiring is shown below: 

24 VAC .... YEL  ORG  YEL 

12VDC .... 

+ • 

toi. 

3  2 

With AC input power, wire the 24 VAC with the orange (ORG) lead in the middle terminal. The other two yellow (YEL) leads go to 

the first and third terminals. With DC input, wire in the 12 VDC with positive on the first terminal and the negative on the second 

as shown on the terminal label above. The third terminal is not used with DC input. It is marked NO CON (no connection) on the 

terminal. Each solenoid has one lead attached to the common (C) terminal and the other to each of the 1, 2, or 3. 

For the DCL version with the solar panel, be sure that the proper polarity is used  when connecting the solar  panel  wires to the 

terminal. They should match the battery leads. The latching solenoid leads must also be properly wired. In this model, the red or 

positive lead  from the latching solenoids go to the stations 1-3.  The black lead goes to the common (C) terminal. 

Note: The pressure differential input is on a separate two pin plug in connector. 

The M output is the master valve that closes during the entire backwash cycle to maintain adequate water pressure for efficient 

backwashing. 

FRONT  PANEL  PROGRAMMING 

Turn the POWER switch to ON. After a few seconds, the display will say POWER OK and display the station or IDLE (which means 

it is not backwashing) and a 3 digit backwash count. 

Select the PERIODIC backwash time by rotating to the desired setting. 

Select the FLUSH DURATION. Select about 2 minutes for media, and 20 seconds as a starting point for screen and disk filter. 

Select the DWELL time.  This is the time it takes one valve to close before the next one opens. 

To start a manual cycle, press the MANUAL START button for one second. Starting a manual backwash cycle resets the periodic 

interval time. 

Содержание Alex-Tronix CONT-F2ACDC-DP

Страница 1: ...attached to the common C terminal and the other to each of the 1 2 or 3 For the DCL version with the solar panel be sure that the proper polarity is used when connecting the solar panel wires to the terminal They should match the battery leads The latching solenoid leads must also be properly wired In this model the red or positive lead from the latching solenoids go to the stations 1 3 The black ...

Страница 2: ...sitives de las solenoides de enganche van a las estaciones 1 3 El conductor negro va al terminal comun C Nata La entrada de la presi6n diferencial esta en un conector separado enchufable de conexi6n de espiga dual La valvula maestra M es la de salida que se cierra durante todo el ciclo de retrolavado manteniendo la presi6n adecuada de agua para la eficiencia de este ciclo PROGRAMACION DEL TABLERO ...

Страница 3: ...1 When the unit is filtering display shows IDLE 2 When the PD is activated the display shows I PD meaning IDLE with PD 3 When backwashing it shows the station ON and DWL when it is in DWELL between stations 4 During a power failure the backwash count is maintained and controller will resume with the same station it was on when the powered failed except that it will restart the backwash time CAUTIO...

Страница 4: ...iene la cantidad de cuentas del retrolavado y el controlador reasumira en la misma estaci6n que estaba cuando se interrumpi6 la corriente excepto que iniciara el tiempo de retrolavado PRECAUCIONES 1 No conecte potencia de 115 VAC a un transformador de 230 VAC aun si fuesen 50 o 60 Hz 2 Para entrada de potencia de DC corriente continua quite el transformador y conecte correctamente la fuente de 12 ...

Отзывы: