12.5 Ltr Pressure 

Water Pump

Owner’s Manual

IWP0023

Telephone: 1300 731 137

IMPORTANT:

 Please read all procedures and precautions before installing and using the Ironman 4x4  

Pressure Water Pump. If you have any questions please contact our customer service department.

www.ironman4x4.com

WARRANTY

Содержание IWP0023

Страница 1: ...nual IWP0023 Telephone 1300 731 137 IMPORTANT Please read all procedures and precautions before installing and using the Ironman 4x4 Pressure Water Pump If you have any questions please contact our customer service department www ironman4x4 com WARRANTY ...

Страница 2: ... Male Barb Pull retaining clip back and insert required barb then reposition clip to secure Attach Outlets Water Inlet Water Outlet Retaining Clip Pressure Switch Water Pump Motor Mounting Foot Fittings Straight Male Threaded Barb Page 2 of 8 www ironman4x4 com ...

Страница 3: ...nsions Centre of Feet 8 4 x 9 1cm Product Weight Incl accessories kg 1 9 kgs ELECTRICAL Voltage 12V Amperage 4 0A 9 0A MAX Max Wattage 120W Fuse Rating AUTO FUSE 10A RATING PERFORMANCE SPECIFICATIONS Max Flow 12 5Ltrs Per Minute Pressure Setting 35 PSI Shut Off Duty Cycle Intermittent 1 200 Hrs Max Motor Brush Magnet Thermal Over Load Yes Noise Rating dB 55 dB Water Head Lift 7Mtr ...

Страница 4: ... clamps on hose connections to prevent water leaks The pump s normal oscillation may transmit through rigid plumbing causing noise and possibly loosen or crack components Note If the water supply is below the level of the pump fitting a Non Return Valve is recommended to prevent water running back to the water supply Typical Vertical Horizontal Location and Mounting The following should be conside...

Страница 5: ...ge 5 of 8 Pump Filter and Attachments Dimensions 44 00 的 凹 的 ω 叮 N 1 ID 回 叮 创 47 40 o h 27 00 N 63 40 91 50 82 00mm 24 60mm 24 60mm 24 60mm 53 30mm 70 00mm 63 40mm 91 50mm 27 00mm 47 40mm 44 00mm 45 40mm ...

Страница 6: ...fter installation Has not been used for a while eg Van in storage Water lines need flushing A blockage caused by trapped air Airlock After maintenance occurs or any other changes to the plumbing system are undertaken Connecting a new outlet tap to your existing system When the pump is to be used for the first time ensure that the outlet pipe or any taps connected are fully open This will allow any...

Страница 7: ...ilure if connected Lift end of float switch up if pump runs switch is OK If pump does not run turn manual switch to on position if pump runs automatic switch has failed Pump won t shut off Something under the float if connected Clean under the float to make sure debris is not holding the float up Stuck float if connected Check to see that the float switch moves freely If float action appears slugg...

Страница 8: ...IWP0023 170521 www ironman4x4 com ...