IRIS Energy Smart ES2H40HD045V Скачать руководство пользователя страница 1

Energy Smart

®

 Electric 

Water Heater Controller

100261231

Installation, Operation and 

Troubleshooting Instructions 

®

Table of Contents

Installation and Setup,  2

Operation, 5

Troubleshooting, 7

Regulatory Notices,  11

Содержание Energy Smart ES2H40HD045V

Страница 1: ...ergy Smart Electric Water Heater Controller 100261231 Installation Operation and Troubleshooting Instructions Table of Contents Installation and Setup 2 Operation 5 Troubleshooting 7 Regulatory Notices 11 ...

Страница 2: ...ontrol is set to a relatively low temperature hot water can scald Install thermostatic mixing valves at each point of use to reduce the risk of scalding 3 Install the Controller WARNING Working on an energized circuit can result in severe injury or death from electrical shock Turn power off before performing this installation Check wires with a non contact circuit tester to make sure power is off ...

Страница 3: ...icates that the controller has been reset Step 2 Open a wireless network control panel on your device computer smart phone or tablet A list of available wireless networks should be displayed Figure 4 Step 3 Disconnect your device computer smart phone or tablet from your home s WiFi network You will connect to a different network during the next step Example List of SSIDs Displayed in Available Wir...

Страница 4: ...t started with Iris Before you try to sign in check the following The Energy Smart Electric Water Heater Controller must be connected to your home s wireless network Your home s wireless network must be connected to the Internet The controller must be enabled before you can control and monitor your water heater through Iris See 3 Install the Controller Steps 6 through 9 For more information about ...

Страница 5: ... Troubleshooting section to determine its meaning Reset Button The reset button is located toward the center of the electric water heater controller Figure 1 To reset the controller and put it in Access Point AP Mode 1 Press the reset button 8 times with a paper clip about once per second until you hear a beep See Figure 8 The beep means that the controller has been disconnected from the WiFi netw...

Страница 6: ... the following water heater parameters through Iris operating mode temperature set point up to Maximum Set Point and heating schedule Estimated Hot Water Level may be viewed through Iris For safety reasons your temperature setting through Iris cannot exceed the temperature that is programmed into your water heater s user interface For example if the user interface on the water heater is set at 120...

Страница 7: ...e the water temperature setting though Iris It doesn t work Why won t it work A For safety reasons your temperature setting through Iris cannot exceed the temperature that is programmed into your water heater s user interface For example if your water heater itself is set to 110 F then 110 F is the highest temperature setting allowed in Iris Check your water heater s temperature setting and adjust...

Страница 8: ...dy This flash code indicates that the controller is disabled This may occur following a power outage To enable the controller unlock the water heater s user interface and touch the Grid Enabled button The Grid Enabled button LED will turn on See Figure 9 NOTE When unlocking the user interface you must touch the lock button for at least 5 seconds The Lock icon will disappear from the screen The fol...

Страница 9: ...ess controller will operate as an access point to connect to a WiFi local network See Note 2 at the end of the troubleshooting section Status LED Steady on brightens briefly when posting Description Connected Posting Beeper None Button Press Effect To change the controller s state to Access Point AP mode press the reset button 8 times with a paper clip about once per second until the controller be...

Страница 10: ...nternet access Status LED 2 Flashes PAUSE 3 Flashes PAUSE 3 Seconds On Off Repeats Description No Connectivity Beeper None Button Press Effect None Notes Remedy Call 855 469 IRIS Help is also available at www lowes com iris support Status LED Brightens Gradually Dims Gradually Description Search Mode Beeper None Button Press Effect To change the controller s state to Access Point AP mode press the...

Страница 11: ...s subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection ag...

Страница 12: ...th Corporation All Rights Reserved Energy Smart is a registered trademark of American Water Heater Company All Rights Reserved IRIS and IRIS and Wave Design are trademarks or registered trademarks of LF LLC All Rights Reserved ...

Отзывы: