![Irenis MPE-2000 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/irenis/mpe-2000/mpe-2000_user-manual_2090188009.webp)
IRENIS MPE-2000 MPEG-2 Encoder
User’s Manual
7
/
34
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no
less than 25mm
2
.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding
wire should be as short as possible and avoid circling. The area of the conduction
between grounding wire and grounding strip should be no less than 25mm
2
.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the
power switch, fuse, power supply socket is just beside ,whose order goes like this, power
switch is on the left ,power supply socket is on the right and the fuse is just between
them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC
power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent
way, say, share the same ground with other devices. When the device adopts united
way, the grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to Encoder, user should set the power switch to
“OFF”.