Sensor Installation
50
Modline 5
Dimensions are in inches and (millimeters). Do not scale.
3.10
Accessory Combinations with Break-out Drawings
3.10.1
Recommended Accessory Groupings
The table below lists the eighteen recommended accessory groupings. Exploded views of the groups
are shown on the following two pages.
The recommended groupings for Sensors with the Dirty Window Detector are identified in the DWD
column. See Section 3.8
, for more information. Groups are illustrated
with dimensions in Section 3.11
Installation Drawings and Illustrations
Group
Mounting Option
Required Accessories
DWD
See Notes
1
¼-20 Bolt Pattern Mount
UAA
N. R. (1)
2
Large Flange Interface Mount
UAA
MFL
Add ESA (3)
3
Air Purge with ¼-20 Bolt Pattern Mount
UAA
APA
Add ESA (2)
4
Air Purge with Small Flange Mount
UAA
APA
MFS
Add ESA (2)
5
Air Purge with Large Flange Mount
UAA
APA
MFL
Add ESA (2)
6
Right Angle Base Mount
UAA
RAM
N. R. (1)
7
Right Angle Mount with Air Purge
UAA
RAM APA
Add ESA (2)
8
Right Angle Mount with Large Flange.
This group requires an ESA for clearing the
RAM
UAA
RAM
MFL &
ESA
ESA Included
Note 3
9
Right Angle Mount with Air Purge
UAA
RAM APA
MFS
Add ESA (2)
10
Right Angle Mount with Air Purge
UAA
RAM APA
MFL
Add ESA (2)
11
Water Jacket, Air Purge and Small Flange
APA
WJA
MFS
Add ESA (2)
12
Water Jacket with Large Flange Mount
WJA
MFL
Add ESA
(3 and 5)
13
Water Jacket, Air Purge and Large Flange
APA
WJA
MFL
Add ESA (2)
14
Water Jacket, Base Mount
WJA
BMA
N. R. (1)
15
Water Jacket, Base Mount, Air Purge
APA
WJA
BMA
Add ESA (2)
16
Water Jacket, Base Mount and Large Flange
WJA
BMA
MFL
Add ESA
(3 and 5)
17
Water Jacket, Base Mount, Air Purge
and Small Flange
APA
WJA
BMA MFS
Add ESA (2)
18
Water Jacket, Base Mount, Air Purge
and Large Flange
APA
WJA
BMA
MFL
Add ESA (2)
DWD is Dirty Window Detector Option. See ESA on previous page for more information. Also see Sections 3.8
WJA – Water Jacket Accessory Description and Dimensions
Notes:
1.
N. R. = Group Not Recommended for Sensors with DWD.
2.
USE the ESA and APA air purge with clean air for air purging and stray radiation shielding. Use APA without air to
create a dead air space zone and shielding. The use of an APA is required for large targets over 1000
C.
3.
The ESA with MFL provides dead air space and stray radiation shielding. Add an AA-3 air purge accessory for air
purging. See Section 3.12
Other Accessories (Sight Tube, Window, WJ-5 Water Cooling)
, page 60 for AA-3
information. These combinations not recommended for large targets over 1000
C.