1–7
Section 1 — INTRODUCTION
1.6 SPECIFICATIONS
The following specifications are common to all Series of MODLINE 4:
Operating Wavelength Region:
Varies by Series (see Table 1.1)
Emissivity Range:
Adjustable from 0.10 to 0.99 in 0.01 increments
Power Supply and Load Requirements:
Input voltage: 24V direct current (dc) nominal16V direct
current (dc) minimum to 40V direct current (dc) 20mA
maximum. In order for the MODLINE 4 to meet
European Electromagnetic Compatibility Directive
,
a CE version power supply is required.
Load resistance:
≤
1 ohm at 16 to 24V direct current;
1200 ohms at 40 V direct current (see Section 2.4 for
additional information)
Fuse Rating:
For customer supplied power supplies, the power supply
must be fused such that at 40V direct current the current
(I) level must be less than 4 amps. At 16V direct current
the current (I) cannot exceed 8 amps and the power
supply total output must not exceed 150 VA.
Output Current:
4 to 20 mA direct current
Response Time:
Continuously adjustable from approximately
(to 95% of any change in input)
0.15 sec to 10 sec
Peak Picker Decay Range:
Continuously adjustable from approximately
(for models with Peak Picker)
15 sec to 30 min for full-scale decay
Humidity Limits:
0 to 90% non-condensing
Enclosure Material:
Aluminum
Weight:
Standard Enclosure: 2.6 lbs (1.2 kg)
Water-cooled Enclosure: 20 lbs (9.25 kg)
Содержание Modline 4
Страница 3: ......
Страница 5: ......
Страница 6: ......
Страница 34: ......
Страница 35: ......
Страница 36: ...Section 2 INSTALLATION 2 21 ...
Страница 37: ...Section 2 INSTALLATION 2 22 ...
Страница 49: ...Section 4 MAINTENANCE SERVICE 4 4 NOTES ...
Страница 79: ...Section 6 APPLICATIONS GUIDE 6 24 ...