Operation of Unit 

 

1.  Mount the laser in a manner such that the beam will strike a target capable of absorbing 

up to 180 Watts of power. Make sure that the airflow openings are clear of any 
obstructions.   

 

2.  Confirm that the signal connections to the laser are secure and tight.  Make sure that 

the power supply is correctly adjusted and is capable of delivering a minimum of the 
rated amps plus 2 amps margin. 

 

3.  Connect the laser power leads to DC, Red + using at least 10-gauge wire. The power 

supply can affect laser performance!  Use a high-quality, well-regulated supply. 

 

4.  Power up the DC supply.  The fans should start. 

(The “F” fan option, when programed, 

will not start the fans until the laser reaches a preset temperature.) 

 

5.  Make sure the "INTERLOCK" switch is down or off, or the interlock line is ungrounded. 

 

6.  The Key Switch line must be toggled from off to on to arm the laser.  If the switch is 

closed when power is applied, turn it off and then on.  There will be a 6 second delay 
before the green "READY" light lights up. 

(This switch must be toggled to arm the 

system after power up.) NOTE: This function depends on the software version 
and programing.  OEM lasers are shipped without this function. 

 

7.  When the system arms to "READY", if the tickle is being applied, the "LASE" light 

should also light up when the interlock is enabled.  The "LASE" light will get brighter as 
the power increases; this is normal. 

 

8.  The 

“Mod Hi” connection to the laser requires that the command signal contain a tickle 

pulse of 1 to 3 

S at 5,000 Hz when the laser is not being commanded to fire.  Tickle 

rates of greater than 5,000 Hz will result in dangerous conditions (possible unexpected 
low level emissions).  When the laser is being commanded, the modulation rate can 
reach up to 200 KHz.  

NOTE: OEM lasers may be shipped with the tickle function 

disabled.  In this case, the user must provide the correct tickle protocol at all 
times. 

 

9.  Make sure there is enough cool air available to dump the heat!  Do not obstruct the air 

flow in any way or modify the fans.  The laser should not be near heaters or other heat 
sources that increase the ambient fan inlet temperature. 

 

 

 

Содержание Infinity 1510

Страница 1: ...92 3005 MADEinUSA OPERATOR S MANUAL Infinity Series CO2 Laser Models 155 through 1512 www Iradion com...

Страница 2: ...wer Cable All Lasers 12 Connector RJ 45 All Lasers 12 Connector HD 15 Lasers Shipped AFTER January 1 2016 13 Connector HD 15 Lasers Shipped BEFORE January 1 2016 14 Nominal Operating Voltages 15 F Typ...

Страница 3: ...aser equipment Terms Certain terms are used throughout the manual or on the equipment labels Please familiarize yourself with their definitions and significance Danger Imminent hazards which if not av...

Страница 4: ...tions from metallic surfaces Enclose the beam path whenever possible Exposure to direct or diffuse CO2 laser radiation can seriously burn human or animal tissue which may cause permanent damage This p...

Страница 5: ...als being processed should be thoroughly evaluated and the adequacy of provisions for fume extraction filtering and venting should be carefully considered Review the following reference for further in...

Страница 6: ...6 Label Locations...

Страница 7: ...typical for this product family when incorporated for intended use A risk of injury when lifting or moving the unit B risk of exposure to hazardous laser energy through unauthorized removal of access...

Страница 8: ...Name Infinity Model Number 15XX Conforms to the following Directive s and Standard s Applicable Standard s IEC 60825 1 3rd Ed 2014 Safety of Laser Products EN 55011 2009 A1 2010 Group 2 Class A ISM e...

Страница 9: ...t Name Infinity Model Number 15XX To comply with RoHS II all CE marked products require a Declaration of Conformity DoC and that a technical file be made available upon request For finished EEE where...

Страница 10: ...of these safety features are available and it is expected that the user will apply them and fully comply with all CDRH requirements Available Safety Features The following safety features are availabl...

Страница 11: ...ges under the cover that will cause serious RF burns to the skin if touched Caution The lasers are waveguide lasers with a slab unstable optical resonator The resulting elliptical beam is corrected by...

Страница 12: ...wire to power supply Ground Red Power VDC positive connection 10 gauge wire to power supply Connector RJ 45 All Lasers Designation Pin Description Comment RJ 45 1 Modulation High in TTL relative to G...

Страница 13: ...ch in Ground this line through key switch to arm laser Page 10 HD 15 Pin 7 Fault LED drive pin Signal to drive an LED directly with grounded cathode 5V 33mA 150 series resistor HD 15 Pin 8 Forward Mon...

Страница 14: ...6 Key Switch in Ground this line through key switch to arm laser Page 10 HD 15 Pin 7 Fault LED drive pin Signal to drive an LED directly with grounded cathode 12V at 25mA 470 series resistor HD 15 Pi...

Страница 15: ...g Voltages Model Number 155 155 9 3 156 156 9 3 158 1510 1512 DC Voltage 36V 45V 40V 50V 45V 50V 50V F Type Lasers Current production lasers are marked for example as 156F These lasers are designed to...

Страница 16: ...6 second delay before the green READY light lights up This switch must be toggled to arm the system after power up NOTE This function depends on the software version and programing OEM lasers are ship...

Страница 17: ...dion LCC Comm Protocol_v1 5 document The laser command line modulation high requires a 1 to 3 Sec pulse repeated at 200 Sec intervals when there is no output commanded There is an adjustable pulse str...

Страница 18: ...4 high and the RJ 45 pins 1 high and 6 low are designed to allow either floating or grounded input modes Both the High and Low pins should be used in either case A software setting made through the R...

Страница 19: ...be detected by viewing the LED indicators on the rear of the laser The signals monitored with LEDs are LASER READY Lights up when the laser controller is ready for operation OVERTEMP Lights up when th...

Страница 20: ...cooling connections The rear plate of these lasers is pictured below Cooling Specifications Flow Rate 3 78 7 56 liters minute Water Temp Non Condensing 18 C to 24 C Inlet Pressure 413kPa Hardness 250...

Страница 21: ...control corrosion and algae as recommended by the manufacturer of the chiller Use high quality water such as distilled or deionized water to avoid scale buildup Keep the concentration of water at abov...

Страница 22: ...ions indicate The chart below shows the dew point at various air temperatures and relative humidity To determine the dew point temperature measure the air temperature and relative humidity Draw a hori...

Страница 23: ...functions are Get Status Get Options Get Laser Serial Number Set Auto Fan Enable if this hardware option is available Set Auto Fan Disable if this hardware option is available Set Mod Low Grounded Set...

Страница 24: ...24 Mechanical Outline...

Страница 25: ...m 10 6 m 10 2 m 10 6 m Rise Time S 75 75 75 75 75 Pulse Duration S 10 200 10 200 10 200 10 200 10 200 Duty Cycle 0 100 0 100 0 100 0 100 0 100 Power Stability Fan Cooled from cold start 6 6 6 6 6 Pow...

Страница 26: ...nce mR full angle 5 2 5 2 Wavelength m 9 3 m 9 3 m Rise Time S 75 75 Pulse Duration S 10 200 10 200 Duty Cycle 0 100 0 100 Power Stability Fan Cooled from cold start 7 7 Power Stability Water Cooled f...

Страница 27: ...ical damage to lens RFPA malfunction Fault light is lit The laser is too hot The DC voltage is outside the proper range Indicator Lights Details The following chart is provided for clarity RED FAULT o...