Power voltage
Wireless protocol
Radio frequency
Radio range
Radio Power output
Op. humidity
Op. temperature
Dimensions
230 VAC, 50/60 Hz
Modified Zigbee Light Link (ZLL)
2.4 GHz
Typical 15 m @ indoor
5.72 dBm
Max 95% non-condensation
-10°C ~ 50°C (14°F ~ 122°F)
72H x 72W x 38D mm (w/mounting plate)
The ON-PBD-815 is an optional device of IR-TEC’s OS-NET
wireless mesh network solution exclusively designed to
replace an existing wall switch/dimmer to broadcast manual
on/off/dim control commands to the assigned group lighting,
while also function as a network node.
This sleek, low profile OS-NET device can be mounted into a
standard EURO wall box, operated by line voltage power, and
provide wireless control to the grouped lighting as required.
Each ON-PBD-815 can be assigned to control up to 4 lighting
groups via a 2-way handheld remote programmer, SRP-281.
A screwless snap-on wall plate is supplied to create a
modern, high-end appearance for all spaces. By grouping the
ON-PBD-815 with OS-NET sensors, you can effortlessly
achieve an energy-efficient, code-compliant smart lighting
control through a state-of-the-art wireless sensor mesh
network with manual controls capability for presentation or
special event.
Line Voltage OS-NET Button
INSTALLATION INSTRUCTIONS
OVERVIEW
P/N: 058-81500-002
www.irtec.com
This product may be covered by one or more U.S. patents or patent applications.
Please visit www.irtec.com for more information.
ON-PBD-815 series
Lead the wires and strip the insulation with proper
length for connecting.
Connect the wires with the device according to the
wiring diagram shown above.
NOTE
: The ON-PBD-815 requires connecting neutral
wire for operation. To replace the existing wall switch
with no neutral wire, you may substitute the switched
line wire for the neutral of lighting in accordance with
electrical codes and regulations.
Carefully set the wires and mount the device into the
wall box with screws provided.
NOTE:
Do NOT mount the device upside down.
INSTALLATION
1.
2.
3.
INDOOR USE ONLY
Utilisation a L'interieur Uniquement
AVERTISSEMENT & PRUDENCE
WARNING & CAUTION
Turn power OFF at circuit breaker before installing .
Coupez l'alimentation au disjoncteur avant d'installer.
Unit: mm
30
86
86
72
60
72
54
DIMENSIONS
WIRING DIAGRAM
L
230VAC
N
N L
SPECIFICATIONS
IR-TEC International Ltd. warranties this product to be free
of defects in materials or workmanship for a period of five
years from date of shipment. There are no obligations or
liabilities on the part of IR-TEC International Ltd. for
consequential damages arising out or in connection with
the use or performance of this product or other indirect
damages with respect to loss of property, revenue, profit, or
cost of removal, installation or reinstallation.
WARRANTY
ON
(Ramp UP)
OFF
(Fade down)