SMP/UCD-300
Страница 1: ...SMP UCD 300 ...
Страница 2: ...r this equipment Notice For Model UCD 300 only The provided LAN Cable with a ferrite core shall be used when connect UCD 300 to a PC and do not replace the LAN cable with other LAN cable FCC WARNING This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference r...
Страница 3: ...the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea...
Страница 4: ... BETWEEN DATA COM UNIT AND CONTROL PC 13 PREPARATION BEFORE SOFTWARE USE 14 FOR THE FIRST TIME EXECUTE MANAGEMENT SOFTWARE 14 USER REGISTRATION 14 ACCESS CONTROL OF SOFTWARE 15 CHANGE LANGUAGE 15 NETWORK SETTING 16 CREATE INFUSION PROFILE 16 CUSTOMIZE INFORMATION 20 START STUDY 21 START NEW STUDY 21 CATHETER CONNECTION PLOMB ADMIN LIQUID AND ACTIVATION 23 PUMP DETECTION 25 KVO SETTING START AND CO...
Страница 5: ...oftware and pump will be work by the programmed protocol with accurate low flow rate L H order medical solution infusion In addition the medical solution in the reservoir can be complimented and or replace through septum by transcutaneous even after implanted in an animal Accessories which included in iPRECIO STD System iPRECIO system configured with the following accessories Small Lab animal micr...
Страница 6: ...tion Number Top surface Bottom surface name Refill septum Outlet tube Auxiliary Wire antenna for radio communication Reservoir Micro cam Pump ID label Power switch LAN cable connect port AC Adaptor connect port Antenna The antenna is permanently fixed 6 www iprecio com ...
Страница 7: ...iPRECIO SMP UCD 300 Quick guide ver 1 0 0 j Work flow A study performed with iPRECIO を normally follow work flow below 7 www iprecio com ...
Страница 8: ...ETCH for replace always need the RMA format and ship back through original sales channel Duration of guarantee iPRECIO Micro Infusion Pump SMP 300 24 months after manufacturer iPRECIO Management System IMS 300 12 months after shipping date This warrantee represent any other warrantee and include an implied consent of merchantability and dedicated fitness for purpose but not limited to Liability Li...
Страница 9: ...408 0 5 384 1 0 360 5 0 216 10 0 144 Please note that below condition makes shorter battery life In case of kept certain period of time without use after power on After power on internal circuit becomes active and consume battery power by standby power requirement In case of not storage under proper circumstances Under frequent temperature swing or exposed in over storage temp range in spec may ca...
Страница 10: ...errite core Install iPRECIO management software PC setting should be Off the screen saver Get into the control panel Power option of Change when PC sleep and set Put the computer to sleep Never 1 Run the setup exe in a install CD 2 When the startup window appeared click Next Then setup wizard window comes up click Next again 3 Chose the program files store folder and click Next Subsequently confir...
Страница 11: ...ars click Close 5 Check start menu that the following software installed iPRECIO Management Software IMS 300 Utility Base Station Manager Utility Pump Database Manager 6 Three of those software has been installed then the management software install is successful 11 www iprecio com ...
Страница 12: ...lug in the AC Adapter to data communication unit and connect with the PC which the management software installed by cross over type LAN cable Connect to LAN port of Control PC Plug in the AC Adapter to outlet 100 240V 50 60Hz Ferrite core attached end shall be connected to UCD 300 12 www iprecio com ...
Страница 13: ...ty and input IP address below IP Address 192 168 1 11 Subnet mask 255 255 255 0 Then press OK to finalize The Data communication unit factory default IP address configuration is 192 168 1 10 If IP address doesn t work by usage environment with default configuration please change IP address in accordance with Appendix A How to change IP address of the Data communication unit 5 With that the Data co...
Страница 14: ...ill be active to change User Registration 1 Input required information in the user registration window The asterisk marked item below are mandatory Institution Department Administrator 2 In addition at least one operator registration required at this time Input operator s User Name Login ID and Password Confirmation required then click on Add tab The operator will be listed in right table 3 To use...
Страница 15: ...reach the management software To permit to access the software check the Enable Access Control in the user registration window Once use control function is active every time Login ID and Password is required whenever the software executed Please note Login ID and Password When forgot password then software access will be denied Change Language 15 www iprecio com ...
Страница 16: ... window 5 If the status column shows disconnected check the IP address setting Please refer the TCP IP connection between data com unit and control PC Create Infusion Profile Administration protocol that perform in vivo pump of a subject animal of experiments it is required create in the management software in advance and store as a administration protocol The administration profile should be dete...
Страница 17: ...iPRECIO SMP UCD 300 Quick guide ver 1 0 0 j 3 Add new administration profile click Add button 4 Group profile creating window will be opened 17 www iprecio com ...
Страница 18: ...ry life which calculated as a new battery It may help to create an administration schedule Weight range should be input by maximum to minimum Please do not forget to finalize the data by pressing Enter key Do not refer the battery life when the pump was re use and or re programming The indicated battery life was calculated from the battery capacity as a new one 7 When ditto the same schedule the u...
Страница 19: ...n Profile select intended Infusion Profile and click Edit button If want to eliminate the existing Infusion Profile on the list select the intended Infusion profile to delete and click the Delete button 10 Close the Infusion profile window by clicking Close button 19 www iprecio com ...
Страница 20: ...omize Z menu in the tool bar 2 Input a desire information in the Animal Species Animal Strain and Administration Route then click Add button in the below of each boxes 3 If would like to delete existing information select information and click Del button in the below of each boxes 4 Input the numerical value of KVO Flow Rate and Duration 5 To complete the input value click OK button in the left bo...
Страница 21: ...n to be able to deselect individual animal that is difficult to continue Administration by some trouble KVO Change medical solution Administration The Data access Radio system of iPRECIO is not Broadband type in use For that reason the management system can control only one pump in the same time then it may require long time to complete the following data communication Pump detection Start KVO Abo...
Страница 22: ...up Input intend animal number in the Number of Animals and click Set button Default Number of Animal is 20 The information input column will be active in answer to input animal number 5 Input and select by pull down for except Pump ID and Calibration Factor such as individual information Animal ID weight g etc 6 Can copy and paste of the column which already input individual information to another...
Страница 23: ...ecause once a pump switched on the internal cam will start moving to the initial position to block the inner tube 1 Open pump pre sterilization pack in clean environment 2 Cut replace tube and or catheter connection of pump as necessary Each pump dead volume can be calculated in KVO setting so keep final tube length and inner diameter or measured dead volume need to be recorded 3 Fill the admin in...
Страница 24: ...ion successfully inner cam rotates about 100 seconds and most rear pin block the tube When a bland new pump in use 6 After activate with switch on a pump is ready to implant to an animal under test Factory configured Block tube mode Once activate an infusion pump it is impossible to turn off power of the pump 24 www iprecio com ...
Страница 25: ...mp detected then click Next button KVO setting start and complete KVO is abbreviate of Keep Vein Open semantics to prevent the catheter edge clog by continuous liquid dosing by low flow rate Be normally administrate biocompatible liquid such as saline as KVO by low flow rate after implant surgery and prevent clog of catheter end during animal healing period After animal comeback form the surgery t...
Страница 26: ... started During KVO is running please DO NOT STOP the management software 5 When the pre set KVO period will end pumps will stop and Pump status changes into Finished Click Next the injection schedule setting All of animal looks fully recovered before pre setting KVO period you can abort all KVO by clicking abort as a pack and start administration schedule When some animal can not heal enough duri...
Страница 27: ...ministration will be staggered from set time in that value 4 If the proper infusion group name does not found then create new one Please refer Create Infusion Profile 5 After all animal are assigned to profile group click Next button Start Infusion Protocol 1 Infusion Protocol window comes up 2 Click Start all or click start for individual animal to start Infusion Protocol During Infusion Protocol...
Страница 28: ...n click Enter button For detail please refer Replace and or refill drag solution Nest chapter 4 The estimated remain solution volume is shown by calculated from infusion schedule and duration in the bottom of window Also software alarm will be appear when the calculated volume reaches the Alarm Setting volume 5 The Infusion Profile Graph locates in the left side of window Clicking Time Unit button...
Страница 29: ...y fill the replacing solution into syringe and refill it to reservoir To restock the drag solution just fill the solution in a loaded syringe through the skin to port 5 Input Refill Time and Volume click Enter button When executed by dose mode input new weight and click Calculate button recast New Concentration result will be displayed to keep dose condition 6 After fix the Refill Log the table re...
Страница 30: ... click Study End Save Study file 1 Click Save Study from the File F in menu bar The data file stored in C Users XXX AppData Local iPRECIO study 2 The save data can be loaded from Open in the File F in the menu bar Export Study file 1 Chose Export from the File F in menu bar 2 Select folder to export save with file name 3 The exported data format is csv To view the data simply import it by regular ...
Страница 31: ...L hr Discharge flow by 360 degree roll of cam 3 4μL Infusion accuracy 5 Under pressure 0 80cmH2O Battery Life Continuous motion FR 0 1μL hr 19days FR 10 0μL hr 1 week Power on Activation By pressing down of the power on nub switch on the bottom of pump to pump starter Coinstantaneously activated Once activated it s not reversible to switch off Size 24 8 L 15 0 W 7 2 H mm Except accompanying cathet...
Страница 32: ...AC adapter cable included Weight 73g Cable length 1 85m I P 100 240V 50 60Hz 25VA O P DC 5V 2A Size and Weight 120 L 77 W 31 H mm 167g STD accessory Anchorage to cage Velcro LAN cable with ferrite core 3m 1 cable Management software Supported OS Windows XP Windows 7 32bit Japanese English ...