background image

CONNECT 

PRO

WALLSTATION

1

72350 - CONNECT PRO WallStation Black

72351 - CONNECT PRO WallStation White

Содержание CONNECT PRO 72350

Страница 1: ...CONNECT PRO WALLSTATION 1 72350 CONNECT PRO WallStation Black 72351 CONNECT PRO WallStation White ...

Страница 2: ... Station holding and charging the IPORT CONNECT Case Cover Plate The removeable plastic cover that attaches to the WallStation covering the label and Screws IPORT Security Tool The orange handled 1 5mm hex tool used for locking and unlocking IPORT Products Product Info Page www iportproducts com cpwallsta tion Thank you for purchasing the all new IPORT CONNECT Platform We hope you enjoy this revo ...

Страница 3: ...tall Then click on the title to be directed to the appropriate install steps New Construction using Cat 6 Cable pg 4 Existing Construction using Cat 6 Cable pg 15 Upgrading a LAUNCH WallStation pg 25 New Construction using 14 2 Wire pg 32 Existing Construction using 14 2 Wire pg 45 WALLSTATION INSTALL OPTIONS ...

Страница 4: ...LSTATION 4 1 Determine the desired location of the IPORT Connect Pro WallStation will live when the construction is completed IPORT CONNECT Pro WallStation Install New Construction Cat6 Before Construction is complete ...

Страница 5: ...ctrical box or low voltage ring in the desired location of the WallStation NOTE The CONNECT PRO WallStation will cover a 1G electrical box only A 2 Gang electrical box will interfere with the mounting hardware 1G Electrical Box New Constructions Cat6 ...

Страница 6: ...8B from the WallStation location to a nearbyAC outlet closet or network rack location and terminate the other endof the cable the same as before NOTE Make sure to secure the Cat6 cable appropriately onto the Electrical box or Low Voltage ring to retrieve at a later time New Constructions Cat6 ...

Страница 7: ...allStation After Construction 1 Terminate the Cat6 with an RJ45 Connector if not done so previously using T568A or T568B standards 2 Remove the WallSation Drywall anchors and Screws from the box and place on a table x4 x4 New Constructions Cat6 ...

Страница 8: ...CONNECT PRO WALLSTATION 8 3 Insert the WallStation into the 1G box New Constructions Cat6 ...

Страница 9: ...ION 9 4 Use a leveling tool to level the WallStation and mark the 4 locations for the provided Anchors Remove the WallStation from the 1G Box 5 Screw the 4 provided anchors into the wall where marked New Constructions Cat6 ...

Страница 10: ...J 45 to TE Connector provided to the Cat6 cable and onto the white TE connector WallStation DC Adapter New Constructions Cat6 Zip tie the Connector to the DC board for added cable retnetion Label wire WARNING Only for DC Low Voltage Not for PoE ...

Страница 11: ...ck into the 1G box and use the provided screws to attach the WallStation to the wall IMPORTANT Make Sure to position the WallStation with the Up Arrow facing up Use a leveling tool to level the WallStation and hand tighten the screws New Constructions Cat6 ...

Страница 12: ...CONNECT PRO WALLSTATION 12 8 Attach the WallStation Cover Plate over the WallStation making sure to alight the positioning notch with the tooth on the WallStation New Constructions Cat6 ...

Страница 13: ... the RJ 45 to DC Connector at the other end of the Cat6 Cable 10 Connect the provided DC power adapter into the other end of the RJ 45 DC adapter and plug in the power adapter into an AC outlet New Constructions Cat6 Grommit not included ...

Страница 14: ...CONNECT PRO WALLSTATION 14 For a clean finished look place the Connector and DC barrel plug back throug the grommit into the wall Grommit not included ...

Страница 15: ...CONNECT PRO WALLSTATION 15 11 Place a Case with an iPad installed onto the WallStation to determine power was installed properly and the iPad charges New Constructions Cat6 COMPLETE ...

Страница 16: ...TION 16 Installing the WallStation in Existing Construction Cat6 1 Determine the desired location of the IPORT Connect Pro WallStation 2 Use a 2 3 4 70mm hole saw to cut a hole in the desired location of the WallStation X ...

Страница 17: ...WallStation into the 2 3 4 inch hole and use a leveling tool to level the WallStation Mark the 4 locations for the provided Anchors 4 Remove the WallStation form the wall once you have marked the 4 anchor locations Existing Constructions Cat6 ...

Страница 18: ...CONNECT PRO WALLSTATION 18 5 Screw the provided anchors into the wall where marked Existing Constructions Cat6 ...

Страница 19: ...CONNECT PRO WALLSTATION 19 6 Use the 2 3 4 inch hole to fish a Cat6 cable to a nearby AC outlet closet or network rack Existing Constructions Cat6 Grommit not included ...

Страница 20: ... PRO WALLSTATION 20 7 Terminate both ends the Cat6 with an RJ45 Connector using T568A or T568B standards Existing Constructions Cat6 Label wire WARNING Only for DC Low Voltage Not for PoE Grommit not included ...

Страница 21: ...TATION 21 8 Connect the RJ 45 to TE Connector provided to the Cat6 cable and onto the white TE connector WallStation DC Adapter Existing Constructions Cat6 Zip tie the Connector to the DC board for added cable retnetion ...

Страница 22: ...o the wall and use the provided screws to attach the WallStation to the wall anchores IMPORTANT Make Sure to position the WallStation with the Up Arrow facing up Use a leveling tool to level the WallStation and hand tighten the screws Existing Constructions Cat6 ...

Страница 23: ...CONNECT PRO WALLSTATION 23 10 Attach the WallStation Cover Plate over the WallStation making sure to alight the positioning notch with the tooth on the WallStation Existing Constructions Cat6 ...

Страница 24: ...he RJ 45 to DC Connector at the other end of the Cat6 Cable 12 Connect the Provided DC Power Adapter into the wall and connect the barrel connector to the other end of of the RJ 45 DC adapter Existing Constructions Cat6 Grommit not included ...

Страница 25: ...CONNECT PRO WALLSTATION 25 For a clean finished look place the Connector and DC barrel plug back throug the grommit into the wall Grommit not included ...

Страница 26: ...CONNECT PRO WALLSTATION 26 13 Place a Case with an iPad installed onto the WallStation to determine power was installed properly and the iPad charges Existing Constructions Cat6 COMPLETE ...

Страница 27: ...CONNECT PRO WALLSTATION 27 Upgrading a LAUNCH WallStation to CONNECT PRO 1 Remove the old LAUNCH WallStation from the wall making sure to keep the existing anchors installed into the wall ...

Страница 28: ...CONNECT PRO WALLSTATION 28 2 Disconnect the two wires in the wallfrom the green phoenix connector Upgradeing LAUNCH WallStation ...

Страница 29: ... Phoenix connector to the existing wire ran in the wall Next connect the TE cable into the back of the white TE Connector on the WallStation DC Adapter Upgradeing LAUNCH WallStation Zip tie the Connector to the DC board for added cable retnetion ...

Страница 30: ...t the CONNECT WallStation into the wall opening from the previous LAUNCH WallStation IMPORTANT Make Sure to position the WallStation with the Up Arrow facing up Use a leveling tool to level the WallStation Upgradeing LAUNCH WallStation ...

Страница 31: ...CONNECT PRO WALLSTATION 31 5 Use the old screws or provided screws to attach the WallStation to the preinstalled anchors Upgradeing LAUNCH WallStation ...

Страница 32: ...CONNECT PRO WALLSTATION 32 6 Attach the WallStation Cover Plate over the WallStation making sure to alight the positioning notch with the tooth on the WallStation Upgradeing LAUNCH WallStation ...

Страница 33: ...CONNECT PRO WALLSTATION 33 7 Place a Case with an iPad installed onto the WallStation to determine power was installed properly and the iPad charges Upgradeing LAUNCH WallStation COMPLETE ...

Страница 34: ...TATION 34 IPORT CONNECT Pro WallStation Install New Construction 2 Wire Before Construction is complete 1 Determine the desired location of the IPORT Connect Pro WallStation will live when the construction is completed ...

Страница 35: ...ctrical box or low voltage ring in the desired location of the WallStation NOTE The CONNECT PRO WallStation will cover a 1G electrical box only A 2 Gang electrical box will interfere with the mounting hardware 1G Electrical Box New Construction 2 Wire ...

Страница 36: ...ire cable from the WallStation location to a nearbyAC outlet closet or network rack location NOTE Make sure to secure the 2 Wire cable appropriately onto the Electrical box or Low Volt age ring to retrieve at a later time New Construction 2 Wire ...

Страница 37: ...ECT PRO WALLSTATION 37 Installing the WallStation After Construction 1 Locte the 1 gang boxed saved for the wallstation and locte the end of the 2 wire for power New Construction 2 Wire Grommit not included ...

Страница 38: ...CONNECT PRO WALLSTATION 38 2 Remove the WallSation Drywall anchors and Screws from the box and place on a table x4 x4 New Construction 2 Wire ...

Страница 39: ...into the 1G box NOTE the 1G box or Low voltage ring was used to save the space of the WallStation The WallStation was designed to be use without the need for a junc tion box If possible remove the junction box or Low voltage ring New Construction 2 Wire ...

Страница 40: ...CONNECT PRO WALLSTATION 40 5 Use a leveling tool to level the WallStation and mark the 4 locations for the provided Anchors Remove the WallStation from the 1G Box New Construction 2 Wire ...

Страница 41: ...CONNECT PRO WALLSTATION 41 6 Remove the Wall Station and screw the provided anchors into the wall where marked New Construction 2 Wire ...

Страница 42: ...TATION 42 7 Connect the Phoenix to TE cableprovided to the 14 2 wire and onto the White TE Connector on the WallStation DC Adapter New Construction 2 Wire Zip tie the Connector to the DC board for added cable retnetion ...

Страница 43: ...k into the 1G box and use the provided screws to attach the WallStation to the wall IMPORTANT Make Sure to position the WallStation with the Up Arrow facing up Use a leveling tool to level the WallStation and hand tighten the screws New Construction 2 Wire ...

Страница 44: ...CONNECT PRO WALLSTATION 44 8 Attach the WallStation Cover Plate over the WallStation making sure to alight the positioning notch with the tooth on the WallStation New Construction 2 Wire ...

Страница 45: ... the 2 wire to DC Connector at the other end of the 2 wire Cable 10 Connect the Provided DC Power Adapter into the wall and connect the barrel connector to the other end of the Phoenix adapter New Construction 2 Wire Grommit not included ...

Страница 46: ...CONNECT PRO WALLSTATION 46 For a clean finished look place the Connector and DC barrel plug back throug the grommit into the wall Grommit not included ...

Страница 47: ...CONNECT PRO WALLSTATION 47 11 Place a Case with an iPad installed onto the WallStation to determine power was installed properly and the iPad charges New Construction 2 Wire COMPLETE ...

Страница 48: ...TION 48 WallStation Install Manual Existing Construction 2 Wire 1 Determine the desired location of the IPORT Connect Pro WallStation 2 Use a 2 3 4 70mm hole saw to cut a hole in the desired location of the WallStation X ...

Страница 49: ...allStation into the 2 3 4 inch hole and use a leveling tool to level the WallStation Mark the 4 locations for the provided Anchors 4 Remove the WallStation form the wall once you have marked the 4 anchor locations Existing Construction 2 Wire ...

Страница 50: ...CONNECT PRO WALLSTATION 50 5 Screw the provided anchors into the wall where marked Existing Construction 2 Wire ...

Страница 51: ...CONNECT PRO WALLSTATION 51 6 Use the 2 3 4 inch hole to fish a 14 2 cable to a nearby AC outlet closet or network rack Existing Construction 2 Wire ...

Страница 52: ...TION 52 7 Connect the Phoenix to TE cableprovided to the 14 2 wire and onto the White TE Connector on the WallStation DC Adapter Existing Construction 2 Wire Zip tie the Connector to the DC board for added cable retnetion ...

Страница 53: ... the wall and use the provided screws to attach the WallStation to the wall anchores IMPORTANT Make Sure to position the WallStation with the Up Arrow facing up Use a leveling tool to level the WallStation and hand tighten the screws Existing Construction 2 Wire ...

Страница 54: ...CONNECT PRO WALLSTATION 54 9 Attach the WallStation Cover Plate over the WallStation making sure to alight the positioning notch with the tooth on the WallStation Existing Construction 2 Wire ...

Страница 55: ...he 2 wire to DC Connector at the other end of the 2 wire Cable 11 Connect the Provided DC Power Adapter into the wall and connect the barrel connector to the other end of the Phoenix adapter Existing Construction 2 Wire Grommit not included ...

Страница 56: ...CONNECT PRO WALLSTATION 56 For a clean finished look place the Connector and DC barrel plug back throug the grommit into the wall Grommit not included ...

Страница 57: ...CONNECT PRO WALLSTATION 57 12 Place a Case with an iPad installed onto the WallStation to determine power was installed properly and the iPad charges Existing Construction 2 Wire COMPLETE ...