MANUAL [
PY740025/26
]
•
Subject to alteration! Version: 22.10.2018
ipf electronic gmbh
• Kalver Straße 25 - 27 • 58515 Lüdenscheid
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
5.8 FIELD OF VIEW
The width of the measuring field can be limited with the FIELD OF VIEW function. All measuring values
outside the set measuring field are ignored. This is particularly useful if, for example, the measuring field
contains an unwanted object that should not be detected.
The measuring field is adapted by software so the width of the visible laser beam does not change.
5.8.1 Manual limitation of the measuring field
For full flexibility, every value in the measuring field can be individually adjusted. The modified measuring field
need not be symmetrical. Even a single limit, e.g. LIMIT LEFT, can be restricted.
•
LIMIT LEFT
•
LIMIT RIGHT
LIMIT RIGHT
( mm)
LIMIT LEFT
( mm)
Left
Right
LIMIT RIGHT
( mm)
LIMIT LEFT
( mm)
Left
Right
0
m
m
Standard installation
Angled installation (FLEX MOUNT)
0
m
m
NOTE
If a reference surface is taught in with FLEX MOUNT, the reference point of that taught-in surface
represents 0. LIMIT LEFT and LIMIT RIGHT are specified from there.
Referenzfläche
(Eingelernt)
Reference line
(Middle of measuring field)
Reference line
(Middle of measuring field)
NOTE
The LIVE MONITOR mode can be used to find the reference point.
This function displays the
LEFT EDGE RISING of objects.
Now an object is slowly pushed toward the presumed zero
point. The zero point is reached when the value 0 mm is shown on the sensor display.
Reference
point
Reference
point
Measuring field
limited
Measuring field
limited
Содержание PY740025
Страница 1: ...Manual for PY740025 26...