Technical Documentation
opti-check
v2.8.2-K11
40/332
ipf electronic GmbH
Lüdenscheid, Germany
9.1.1 Adjusting the image (additional parameters)
Set the exposure time for image acquisition.
NOTE
Please be aware that, if exposure time is extended, images may become blurred because
of movement of the object. In this case, decrease the exposure time until the object
appears sharp, and increase the value for the amplification
(device dependant)
NOTE
For technical reasons, if the exposure time is the same, the
Reduced Resolution
(Binning)
setting will detect higher grey values than at full resolution.
The image can also be brightened using the control gain (
Amplification
).
NOTE
Higher amplification values result in increased image graininess and make stable analysis
more difficult. If sufficient image brightness is not achieved, use external illumination.