Technical Documentation
opti-check
v2.8.2-K11
20/332
ipf electronic GmbH
Lüdenscheid, Germany
6.4.1 Notes on using an incremental encoder
You have two options for operating the device with an encoder:
NOTE
After installation, the inputs must be defined in the software using:
Device → Device settings → Digital I/Os / Inputs
tab
.
1-channel operation (CH-A)
In this mode, every
rising edge
of the signal corresponds to one
pulse for the timing control of the device.
It is not possible to detect the travel direction of the belt.
The maximum frequency of 500 kHz should not be exceeded for reliable operation.
Pin assignment of
the power cable
Connect the encoder CH-A to pin 11 (IN 5; grey-pink).