background image

Page  13

3.  Apply the compound sealant to the inside lip on the rubber side of the new ULPA filter  (See 

No. 2 on Fig. No. 2 above). 

 

4.  Place the new ULPA filter, rubber side down, back onto the arm of the vacuum cleaner.  

 

5.  Tighten  the  new  ULPA  filter  onto  the  arm  using  the  Hex  Bolt  M5  X  135  with  the  2  seal 

washers (1 big and 1 small) in place (See No. 4 on Fig. No. 2 above) 

 

6.  Make sure not to over tighten the Hex Bolt as this can damage the frame of the new ULPA 

filter. 

 

 

6.6. SERVICING OF DOUBLE-INSULATED APPLIANCES 

 

A double-insulated appliance is marked with one or more of the following: The words “DOUBLE 

INSULATION”  or  “DOUBLE  INSULATED”  or  the  double  insulation  symbol  (square  within  a 

square) 

 

 

 

In a double-insulated appliance, two systems of insulation are provided instead of grounding. No 

grounding  means  is  provided  on  a  double-insulated  appliance,  nor  should  a  means  for 

grounding be added to the appliance. Servicing a double-insulated  appliance requires extreme 

care  and  knowledge  of  the  system,  and  should  be  done  only  by  qualified  service  personnel. 

Replacement parts for a double-insulated appliance must be identical to the parts they replace. 

 

 

Содержание PHARMA

Страница 1: ...M VACUUM CLEANER SYSTEM ULPA FILTRATION 99 999 ON 0 12 MICRON AND 99 9995 ON 0 18 MICRON U15 BY MPPS METHOD AS PER EN 1822 TO ENSURE A SAFE WORKING ENVIRONMENT CAREFULLY READ THE FOLLOWING INSTRUCTION...

Страница 2: ...ANUP PROCEDURE OF PHARMA CLOTH FILTER 8 6 2 CLEANUP PROCEDURE OF PHARMA WITH STAINLESS STEEL AISI 316 RECOVERY TANK AFTER USE 8 6 3 SAFE CONTAINMENT CANISTER DISPOSAL AND REPLACEMENT 9 6 3 1 DISPOSAL...

Страница 3: ...OUBLE INSULATED APPLIANCES WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY 1 the vacuum cleaner is designed for dry recovery only do not use when rug or floor is wet 2 to reduce the risk...

Страница 4: ...and anything that may reduce airflow poor ventilation will result in overheating of motor 11 keep hair loose clothing fingers and all parts of body away from openings and moving parts 12 do not pick...

Страница 5: ...cleaner must be equipped with an external ULPA filter 2 Service and operation should only be carried out by trained personnel wearing appropriate garments and breathing apparatus 3 Dispose of collect...

Страница 6: ...ISI 316 RECOVERY TANK Fig No 1 1 Paper filter bag 2 PTFE laminated main cloth filter 3 ULPA filter 99 999 efficiency on 0 12 micron and 99 9995 on 0 18 micron U15 by MPPS method as per EN 1822 A Sucti...

Страница 7: ...r filter bag 2 PTFE laminated main cloth filter 3 ULPA filter 99 999 efficiency on 0 12 micron and 99 9995 on 0 18 micron U15 by MPPS method as per EN 1822 4 HEPA filter 99 995 efficiency on 0 3 micro...

Страница 8: ...er chamber assembly and fasten the lid with the latches 7 Plug in the power cord into an appropriate electrical outlet 8 Connect suction hose to the recovery tank 9 Attach desired tools to the hose Us...

Страница 9: ...he recovery tank 6 Attach desired tools to the hose Use only the recommended cleaning tools supplied with each unit 7 When the unit is to be turned on the operator should be within close proximity to...

Страница 10: ...uces the vacuum s performance The cloth filter may be washed in lukewarm water NOTE ENSURE THAT CLOTH FILTER IS COMPLETELY DRY BEFORE REINSTALLATION IN VACUUM CLEANER 6 2 CLEANUP PROCEDURE OF PHARMA W...

Страница 11: ...Page 9 6 3 SAFE CONTAINMENT CANISTER DISPOSAL AND REPLACEMENT Fig No 3...

Страница 12: ...o 3 and remove power head from filter chamber assembly 5 Disengage latches See C on Fig No 3 and remove filter chamber assembly from safe containment canister 6 Use the supplied adhesive label See B o...

Страница 13: ...e latches See A on Fig No 3 6 4 STORAGE After servicing turn off all controls before unplugging Do not leave vacuum cleaner when plugged in When unplugged from outlet gently roll up the cord to avoid...

Страница 14: ...nsively daily The filter can be replaced every two years if the vacuum cleaner is used less frequently two or three times per week WARNING IF VACUUM IS USED FOR THE RECOVERY OF TOXIC MATERIALS PROPER...

Страница 15: ...CING OF DOUBLE INSULATED APPLIANCES A double insulated appliance is marked with one or more of the following The words DOUBLE INSULATION or DOUBLE INSULATED or the double insulation symbol square with...

Страница 16: ...s Amendment A1 2009 o EN 60335 1 2012 o EN 60335 2 69 2012 THE LOW VOLTAGE DIRECTIVE 2014 35 EU Compliance has been obtained by application of the following standard o EN 60335 2 2 2010 and its amendm...