Page 13
3. Apply the compound sealant to the inside lip on the rubber side of the new ULPA filter (See
No. 2 on Fig. No. 2 above).
4. Place the new ULPA filter, rubber side down, back onto the arm of the vacuum cleaner.
5. Tighten the new ULPA filter onto the arm using the Hex Bolt M5 X 135 with the 2 seal
washers (1 big and 1 small) in place (See No. 4 on Fig. No. 2 above)
6. Make sure not to over tighten the Hex Bolt as this can damage the frame of the new ULPA
filter.
6.6. SERVICING OF DOUBLE-INSULATED APPLIANCES
A double-insulated appliance is marked with one or more of the following: The words “DOUBLE
INSULATION” or “DOUBLE INSULATED” or the double insulation symbol (square within a
square)
In a double-insulated appliance, two systems of insulation are provided instead of grounding. No
grounding means is provided on a double-insulated appliance, nor should a means for
grounding be added to the appliance. Servicing a double-insulated appliance requires extreme
care and knowledge of the system, and should be done only by qualified service personnel.
Replacement parts for a double-insulated appliance must be identical to the parts they replace.