6.3.2. REPLACEMENT OF PHARMA SAFE CONTAINMENT CANISTER
1. Place new safe containment canister on 4W carriage assembly and tighten spade-head
thumb screw
(See "E" on Fig. No. 3)
2. Place cloth filter in filter chamber
3. Place filter chamber assembly on safe containment canister and engage latches.
(See
"C" on Fig. No. 3)
4. Place power head on filter chamber assembly and engage latches
(See "A" on Fig. No.
3)
6.4. STORAGE
After servicing, turn off all controls before unplugging. Do not leave vacuum cleaner when
plugged in. When unplugged from outlet gently roll up the cord to avoid damage.
PHARMA with stainless steel AISI 316 recovery tank
It is recommended that the inside of the recovery tank be cleaned before storing the vacuum.
The inside of the recovery tank should be dry at all times.
PHARMA with safe containment canister
The suction intake of the safe containment canister must be closed using the storage cap