background image

Page 1 of 12 

Drawing   : - TPC445 
Issue 

: - 1 

Date 

: - 02/12/15 

CS90H 

INDUSTRIAL DEHUMIDIFIER 

OWNER’S MANUAL 

E B A C   C S - 9 0 - H    D E H U M I D I F I E R     O W N E R ' S    M A N U A L 

Pure n Natural Systems  |  purennatural.com  |  1-800-237-9199

Содержание CS90H

Страница 1: ...f 12 Drawing TPC445 Issue 1 Date 02 12 15 CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL E B A C C S 9 0 H D E H U M I D I F I E R O W N E R S M A N U A L Pure n Natural Systems purennatural com 1 800 2...

Страница 2: ...ONTENTS Item Description Quantity 10590GH US Dehumidifier 1 3944110 PVC tube 3 8 I D 7 8 M 3086144 Quick release hose coupling 1 TPC445 Manual 1 E B A C C S 9 0 H D E H U M I D I F I E R O W N E R S M...

Страница 3: ...ergy removed during the cooling phase plus the additional heat generated by the compressor The air is therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute...

Страница 4: ...strial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL CS60H HEIGHT 15 2 386mm WIDTH 14 353mm DE...

Страница 5: ...quired humidity level can be set as follows Press the S button once to access the set point Press the or button to change the display to the desired Humidity level Press the S button again to save the...

Страница 6: ...he unit is defrosting the Relative Humidity displayed on the digital controller may increase as a result of the ice frost melting This is quite normal and the display will return to its normal reading...

Страница 7: ...an frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5 In order to check the defrost operation t...

Страница 8: ...d and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor...

Страница 9: ...the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Contact the Factory Service Center 2 Contact the Factory Ser...

Страница 10: ...Tubing 3014338 9 Feet 7 Solenoid Valve 3020837 1 8 Filter Dryer 3020901 1 9 Compressor 3022198 1 10 Defrost Relay 3030269 1 11 Solenoid Coil 3030451 1 12 Capacitor 3030908 1 13 Humidity Controller 30...

Страница 11: ...SCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE WARRANT...

Страница 12: ...ssue 1 Date 02 12 15 E B A C C S 9 0 H D E H U M I D I F I E R O W N E R S M A N U A L Pure n Natural Systems purennatural com 1 800 237 9199 Distributed by Pure n Natural Systems Inc Streamwood IL pu...

Отзывы: