Installation 

Maintenance Mode 

uSTART

®

 will be shipped in 

Maintenance Mode

. The 

solid yellow LED

 

will light while uSTART

®

 is first 

connected to a battery to show it is in 

Maintenance Mode. 

uSTART

®  

is now ready to support the vehicle 

and will automatically enter 

Run Mode

 when the vehicle starts.  

Mounting Location 

uSTART

®

 is designed to mount in the same space as a group 31 battery.  The typical installation location is in 

the battery box of a Class 3 – 6 truck.  uSTART

®

 must be installed in parallel with at least one battery in 

order to function and provide energy.  If there are two or more batteries in a battery box, one can be 

removed to make room for uSTART

®

.   

 

On some truck models the Diesel Particulate Filter After-Treatment System or other exhaust components 

may be located near the battery box.  These systems can generate very high temperatures during operation 

which may cause uSTART

®

 to 149°F (+65°C).  If the vehicle battery box is near the Diesel Particulate 

Filter After-Treatment System or any part of the exhaust, mount uSTART

®

 in a location far away from it or 

install heat shielding capable of preventing uSTART

®

 from experi149°F (+65°C) temperatures under 

worst case conditions. 

Pre-Installation Checks 

1.

 

Test the vehicle starting and charging system prior to installing uSTART

®

 to isolate any pre-existing 

problems.  Refer to Recommended Practice 129A (RP 129A) of the American Trucking Association 
(ATA) Technology and Maintenance Council (TMC) for procedures to test cable connections between 
all starting and charging system components for maximum voltage drop.  Repair any issues found 
before proceeding. 

2.

 

Remove the cables from the negative (-) terminal(s) of the vehicle battery(s). 

3.

 

Remove the cables from the positive (+) terminal(s) of the vehicle battery(s). 

4.

 

All cable terminations and battery terminals should be cleaned thoroughly to remove all oxidation and 
grease. 

5.

 

Test the vehicle battery(s) individually to ensure that they are properly charged.  Remove and replace 
any batteries that are discharged below their specified voltage or failed to meet their CCA rating. 

6.

 

If there is no additional space in a vehicle’s battery box, remove a battery to make room for 
uSTART

®

7.

 

Place uSTART

®

 in the desired mounting location. 

8.

 

Check that uSTART

®

 positive (+) and negative (-) terminals line up with positive (+) and negative (-) 

terminals on remaining battery(s) and vehicle positive (+) and negative (-) battery cables. 

Installation 

In most instances, it is desirable to use existing vehicle cables to connect uSTART

®

 to the vehicle starting and 

charging systems.  If new cables need to be made, the insulation should meet the requirements of SAE J1127, 
SAE J259, and TMC RP 166.  Recommended cable insulations are 125°C rated Cross-Linked Polyethylene 
(SAE J1127 type SGX) and 125°C rated Thermoset Elastomer (SAE J1127 type SGR where flexibility is 

Содержание uST12V0375G31-MDA

Страница 1: ...Contents Model uST12V0375G31 MDA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre Installation Checks 4 Installation 4 Wiring Dia...

Страница 2: ...al information Do not connect in reverse polarity uSTART is protected from up to 28 VDC reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attemp...

Страница 3: ...damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational uSTA...

Страница 4: ...st the vehicle starting and charging system prior to installing uSTART to isolate any pre existing problems Refer to Recommended Practice 129A RP 129A of the American Trucking Association ATA Technolo...

Страница 5: ...TART relates to any batteries being mounted with it uSTART is designed to be installed using the existing Group 31 battery hardware Install uSTART using the existing Group 31 battery hardware and torq...

Страница 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 17 2021 DOC 1 0004 Rev B 2021 Ioxus All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART install Fi...

Страница 7: ...lways be in Maintenance Mode prior to any maintenance If uSTART is connected to a battery the solid yellow LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will...

Страница 8: ...Charge Mode can be accessed through the uSTART App The green LED will be solid and the yellow LED will flash as uSTART charges its ultracapacitors After the charging period finishes the green LED will...

Страница 9: ...ights reserved 9 Installation and Startup Figure 5 Installation Flow Chart uSTART installed and connected to battery MAINTENANCE Mode Solid Yellow LED Start Vehicle and wait 10 Seconds or Switch to RU...

Страница 10: ...reserved 10 Disconnecting uSTART for Service Figure 6 Service Flow Chart Disconnect uSTART Positive Terminal and wait 7 seconds uSTART Previously Installed Solid Green LED RUN Mode Or All LEDs Off St...

Страница 11: ...se uSTART App to put uSTART into JUMP START CHARGE Mode uSTART Previously Installed but vehicle failed start attempt Load may be pulling down Vehicle voltage Shut off All loads and wait for voltage 10...

Страница 12: ...ngine cranking times will cause uSTART to enter fault mode in order to ensure long term product lifetime is not reduced 3 Malfunction Protection The fault condition will not automatically clear and th...

Страница 13: ...ly checked for oxidation or loose connections and cleaned or tightened as necessary No other maintenance is required Poor electrical connections can cause performance problems with uSTART Prior to rem...

Отзывы: