Description 

uSTART

®

 is an ultracapacitor based device that enhances vehicle performance.  uSTART

®

 improves battery life 

by maintaining a vehicle’s voltage under a wide range of load conditions. It supplies nearly all of the cranking 
current during engine starts.  uSTART

®

 stores a relatively small amount of energy compared with a battery, 

but it can deliver engine cranking current for a few seconds or power auxiliary loads for a few minutes.  

Feature Identification  

 

Figure 1: uSTART® Feature Identification 

Unpacking 

Please inspect the shipping carton for signs of damage prior to unpacking. Report any damage to the carton, or 
the contents, to the carrier immediately. Retain all shipping materials until uSTART

®

  is fully inspected and 

determined to be operational. 

uSTART

®

 should be lifted by the module body. The terminals should not be used for hoisting.  

If any parts are determined to be missing or defective an RMA number must be issued prior to returning the 
unit for repair or replacement. Please contact your salesperson or distributor to request an RMA number. 

uSTART

®

 is designed for years of maintenance free operation if handled, installed, and used properly. These 

handling precautions should be observed: 

 

uSTART

®

 should not be stacked  

 

The only tools to be used on uSTART

®

 should be properly sized wrenches for the terminal and 

mounting bolts (hammers, chisels, files or power tools in general should not be used) 

 

Do not drop uSTART

®

; internal damage may occur 

   Positive Terminal (+) 

  Negative Terminal (-) 

Status LEDs 

 

Содержание uST12V0375G31-MDA

Страница 1: ...Contents Model uST12V0375G31 MDA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre Installation Checks 4 Installation 4 Wiring Dia...

Страница 2: ...al information Do not connect in reverse polarity uSTART is protected from up to 28 VDC reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attemp...

Страница 3: ...damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational uSTA...

Страница 4: ...st the vehicle starting and charging system prior to installing uSTART to isolate any pre existing problems Refer to Recommended Practice 129A RP 129A of the American Trucking Association ATA Technolo...

Страница 5: ...TART relates to any batteries being mounted with it uSTART is designed to be installed using the existing Group 31 battery hardware Install uSTART using the existing Group 31 battery hardware and torq...

Страница 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 17 2021 DOC 1 0004 Rev B 2021 Ioxus All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART install Fi...

Страница 7: ...lways be in Maintenance Mode prior to any maintenance If uSTART is connected to a battery the solid yellow LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will...

Страница 8: ...Charge Mode can be accessed through the uSTART App The green LED will be solid and the yellow LED will flash as uSTART charges its ultracapacitors After the charging period finishes the green LED will...

Страница 9: ...ights reserved 9 Installation and Startup Figure 5 Installation Flow Chart uSTART installed and connected to battery MAINTENANCE Mode Solid Yellow LED Start Vehicle and wait 10 Seconds or Switch to RU...

Страница 10: ...reserved 10 Disconnecting uSTART for Service Figure 6 Service Flow Chart Disconnect uSTART Positive Terminal and wait 7 seconds uSTART Previously Installed Solid Green LED RUN Mode Or All LEDs Off St...

Страница 11: ...se uSTART App to put uSTART into JUMP START CHARGE Mode uSTART Previously Installed but vehicle failed start attempt Load may be pulling down Vehicle voltage Shut off All loads and wait for voltage 10...

Страница 12: ...ngine cranking times will cause uSTART to enter fault mode in order to ensure long term product lifetime is not reduced 3 Malfunction Protection The fault condition will not automatically clear and th...

Страница 13: ...ly checked for oxidation or loose connections and cleaned or tightened as necessary No other maintenance is required Poor electrical connections can cause performance problems with uSTART Prior to rem...