Condition 

Item 

To 

Check 

Possible Cause 

Remedy 

uSTART® Problem 

Check for loose electrical connections and battery condition. 

Verify the battery voltage with the vehicle off is above 12V. 

Confirm uSTART® terminals also have above 12 V.  

Disconnect the uSTART® Negative lead for 30 seconds and 

then reconnect. If the Yellow LED does not light, contact 

Ioxus Customer Service. 

uSTART® has stopped functioning. 

Maintenance 

Terminals should be periodically checked for oxidation or loose connections and cleaned or tightened as 
necessary.  No other maintenance is required.  Poor electrical connections can cause performance problems 
with uSTART®

®

. Prior to removal or system maintenance, ensure that uSTART

®

 is in 

Maintenance Mode

.  

uSTART

®

  can be cleaned while in 

Maintenance Mode

 by use of a cloth and simple soap and water solution.  

Avoid the use of hoses or pressurized sprays. 

Storage 

uSTART

®

 can be stored in its original packaging, in a dry place for up to four (4) years.  Observe the 

maximum storage temperature as stated in the product specifications. 

Disposal 

Do not incinerate, crush, or dispose of in trash.  Do not recycle with lead-acid batteries.

 

 

Please recycle according to local codes and regulations for electronic waste. 

Specifications 

Please see data sheet for specifications. 

Содержание uST12V0375G31-MDA

Страница 1: ...Contents Model uST12V0375G31 MDA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre Installation Checks 4 Installation 4 Wiring Dia...

Страница 2: ...al information Do not connect in reverse polarity uSTART is protected from up to 28 VDC reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attemp...

Страница 3: ...damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational uSTA...

Страница 4: ...st the vehicle starting and charging system prior to installing uSTART to isolate any pre existing problems Refer to Recommended Practice 129A RP 129A of the American Trucking Association ATA Technolo...

Страница 5: ...TART relates to any batteries being mounted with it uSTART is designed to be installed using the existing Group 31 battery hardware Install uSTART using the existing Group 31 battery hardware and torq...

Страница 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 17 2021 DOC 1 0004 Rev B 2021 Ioxus All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART install Fi...

Страница 7: ...lways be in Maintenance Mode prior to any maintenance If uSTART is connected to a battery the solid yellow LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will...

Страница 8: ...Charge Mode can be accessed through the uSTART App The green LED will be solid and the yellow LED will flash as uSTART charges its ultracapacitors After the charging period finishes the green LED will...

Страница 9: ...ights reserved 9 Installation and Startup Figure 5 Installation Flow Chart uSTART installed and connected to battery MAINTENANCE Mode Solid Yellow LED Start Vehicle and wait 10 Seconds or Switch to RU...

Страница 10: ...reserved 10 Disconnecting uSTART for Service Figure 6 Service Flow Chart Disconnect uSTART Positive Terminal and wait 7 seconds uSTART Previously Installed Solid Green LED RUN Mode Or All LEDs Off St...

Страница 11: ...se uSTART App to put uSTART into JUMP START CHARGE Mode uSTART Previously Installed but vehicle failed start attempt Load may be pulling down Vehicle voltage Shut off All loads and wait for voltage 10...

Страница 12: ...ngine cranking times will cause uSTART to enter fault mode in order to ensure long term product lifetime is not reduced 3 Malfunction Protection The fault condition will not automatically clear and th...

Страница 13: ...ly checked for oxidation or loose connections and cleaned or tightened as necessary No other maintenance is required Poor electrical connections can cause performance problems with uSTART Prior to rem...

Отзывы: