Quick Manual 

Neutron3-B+ Remote Pulse Collector 

 

 

 

 

Copyright 2020 - ionSign 

www.ionsign.fi 

15.6.2020 

– v1.4 

 

Introducing Neutron3-B: 

1. 

Insert SIM card to its slot, PIN query disabled. 

2. 

Connect the measuring device(s). 

3. 

Insert the battery or remove the battery cover. 
The red led lights up for 10 seconds. 

4. 

Enter the installation mode by pressing the but-
ton inside the device or activating it with a mag-
net from the outside. The device wakes up for 
five  minutes  to  receive  SMS  messages.  The 
red GSM led double blinks when GSM network 
search is active, and blinks when a GSM con-
nection is established. 

5. 

Send a SETTINGS command to the device as 
an SMS. When the command is received, the 
yellow led starts blinking and the device starts 
to establish a server connection. The yellow led 
remains lit when the device is in operation. 

6. 

Securely  close  the  lid  and  mount  the  device 
e.g. to a wall. 

When the installation mode times out, all leds switch off. This is normal. 

The below example command sets device 101 to start collecting hourly pulse data and 

send  it  to  server  services.ionsign.fi, 
path  /cloud/input/  and  port  80,  using 
internet as APN. Device 101 has 4 in-
puts and data is sent one minute after 
24  readings  have  been  collected.  In 
this case, with hourly data, at 00:01. 

 

Refer to section 4 on the next page 

to  compile  your  specific  SETTINGS 
command.  Always  establish  your 
specific SETTINGS parameters from 
your reseller, service provider or  
ionSign.

 

E.g.  JAMAK  2x(2+1)x0,5mm2  instrumentation 
cable can be used between  Neutron3-B+ and the 
meter.  Connect  the  cable  to  the  connector  and 
snap it in place to the terminal block. Cable polarity 
has no significance. 

GSM LED 

Antenna 

SIM card 

Button 

Battery 

connector 

Pulse connectors 

LED 

indicators 

Device 

ID 

Attached 

meters 

Server 

name 

Server 

port 

Server 

path 

Transmission 

delay 

Operator 

APN address 

Measurement cycle:  

15, 30 or 60 (min) 

Example SETTINGS command: 

SETTINGS 

Command 

60 