Страница 1: ...RUGGEDISED TABLET 7 06 0001 User s Manual...
Страница 2: ...in compliance and conform to the European Union s Restriction of Use of Hazardous Substances in Electrical and Electronic Equipment RoHS Directive 2002 95 EC This symbol of CAUTION indicates that ther...
Страница 3: ...quid into openings This may causes fire or electrical shock If one of the following situations arises get the equipment checked by service personnel The power cord or plug is damaged Liquid has penetr...
Страница 4: ...cial or manufacturer which expressly refers to this limited warranty Exclusion of Other Warranties The manufacturer makes no other warranties express or implied The implied warranties for merchantabil...
Страница 5: ...rtex A7 1 1GHz Processor Android 7 1 2 Operation System comply with IP 66 rating WIFI Bluetooth LTE GNSS and 5000mAh rechargeable battery supported 7 IPS Display physical 1280x800 resolution 800cd m2...
Страница 6: ...GPIO Red White Green Yellow Black Voltage range 0 30V Voltage range 0 3 7V Contact Pins 1 2 3 4 5 6 7 No Connection Description 1 Contact Pins 1 2 3 4 5 6 7 8 GPIO69 GPIO1 GPIO2 GPIO3 GPIO4 ACC GND R...
Страница 7: ...PS 1575 42MHz 1 023MHz GLONASS 1597 5MHz 1605 8MHz BeiDou 1561 098MHz 2 046MHz WWAN US Version North America LTE FDD B2 B4 B5 B7 B12 B13 B25 B26 WCDMA B1 B2 B4 B5 B8 GSM 850 1900MHz EU Version EMEA Ko...
Страница 8: ...C 14443 A B up to 848kbit s FeliCa at 212 424 kbit s MIFARE 1K 4K NFC Forum type 1 2 3 4 5 tags ISO IEC 15693 All peer to peer modes Card Emulation Mode from host NFC Forum T4T ISO IEC 14443 A B at 10...
Страница 9: ...urs Power Consumption Normal mode 5 Watt Charging mode 8 Watt Adapter Input AC 100 240C 50 60Hz Adapter Output DC power output 12V 2A Operating Temp 10 C 65 C 14 F 149 F Storage Temp 20 C 70 C 4 F 158...
Страница 10: ...by power consumption the red light is on in charging status when power on And the light will go off if full charged 4 The consumption during power off with docking station around 100mW Sleep and Wake...
Страница 11: ...over with screws 2 3 Charging the Battery Due to shipment the battery is partially drained when the package is delivered to you Be sure to charge the battery to full when you are charging it for the f...
Страница 12: ...process a battery indicator will appear in the status bar showing the charging percentage To view the charge percentage swipe down the Status Bar and you will see the charging percentage b When the ba...
Страница 13: ...Set a shorter timeout of inactivity to allow the screen enter sleep mode Turn off the display if you are not using it Disable the power drawing features like Wi Fi Bluetooth or GPS function if you ar...
Страница 14: ...battery life and lower device temperature To access the battery settings page swipe down the Status Bar in the upper right corner and then tap and hold the BATTERY tile 19 right corner and tap and hol...
Страница 15: ...cable 3 1 1 Connection Connect the device to the computer by using the USB type c cable and open the prompt message of the device The following interface displays Click USB charging this device to cha...
Страница 16: ...nctions I Boot up the tablet by ACC powered II Light up the screen by ACC powered III Close the screen by ACC outage and setting the delay time IV Trigger to shut down the tablet by ACC outage and set...
Страница 17: ...ease refer to Figure 2 1 2 2 and 2 3 Figure 2 1 Figure 2 2 23 system setting 3 3 3 ACC Settings Path ACC settings located in ACC Settings under the category of System in the Settings of Android OS Ple...
Страница 18: ...elow 24 Figure 2 3 3 3 4 ACC Settings ACC settings as shown in Figure 2 4 Figure 2 5 Mark 1 The main switch of the three functions controlled by ACC namely light up the screen close the screen and shu...
Страница 19: ...onnect the GPIO interface of the tablet 25 Figure 2 5 ACC Settings interface 2 Figure 2 6 Screen off delay time setting dialog box Figure 2 7 Shut down delay time setting dialog box 3 4 Using GPIO 3 3...
Страница 20: ...e works normally but not available for adjusting the input or output state of the GPIO ports The State in the third column means the current level state of the GPIO ports it used to show the level sta...
Страница 21: ...e directions are OUT When it displayed as SET_OUT_LOW click it to set all GPIO ports with Direction OUT to low level The low level output is about 0V When it displayed as SET_OUT_HIGH click it to set...
Страница 22: ...ing figure to enter the Root privilege on off function setting interface 2 The root switch setting interface is as follows In the figure 1 is the Root permission on off switcher In the figure 2 is the...
Страница 23: ...icles by Society of Automotive Engineers SAE in 1988 It was first introduced in the United States in 1994 and became a requirement on all 1996 and newer US vehicles Other countries including Canada pa...
Страница 24: ...send info with Hexadecimal format codec 10 The boxes in red means manual clear button click to clear both info in the COM port info receiving boxes 21 3 2 Using Serial Port Demo App Serial Port ID COM...
Страница 25: ...25...
Страница 26: ...4 2 4 1 3 Push the tablet to make it attached the docking via snap joint as fig 4 3 shown 34 Chapter 4 Docking station Using Instruction 4 1 Docking station install steps 4 1 1 Align the tablet to the...
Страница 27: ...as fig 4 4 shown Fig 4 4 4 2 Docking station Disassembly steps 4 2 1 Stretch upwards the buckle to release it from the device as fig 4 5 shown Fig 4 5 4 2 2 Take out the device as Fig 4 6 shown Fig 4...