The Cub Display - Overview
1
Battery charge indicator.
2
Detected gas level.
3
Gas level units (
ppm
or
mg/m3
, depending on how the
Cub is configured).
4
This indicates the gas sensor type selected, e.g.
VOC
or
Volatile Organic Compounds.
5
This symbol appears when a STEL or TWA alarm is
exceeded.
6
If the
TLV STEL
icon is present, on-going calculated
values are being displayed.
Display Screens
IF AN ALARM STATE IS TRIGGERED THE USER SHOULD LEAVE THE HAZARDOUS
ENVIRONMENT AND ACT IN ACCORDANCE WITH NATIONAL SAFETY
REGULATIONS.
The Cub can display a number of different data screens. To cycle through these screens, press the
multi-function button on top of the Cub. When a new screen is accessed the display is illuminated
with a different coloured light, which will turn off after a few moments.
When the display is already lit up, a different screen is displayed every time the multi-function
button is pressed (except when an alarm has been triggered -
). If the display is not lit up,
the multi-function button must be pressed once to light it up and then again to show the next
screen.
The screens are listed below in the order that they are accessed.
Main gas detection display screen.
Displayed by default when a Cub is turned on.
Displays the on-going live TLV / STEL.