background image

Ion Technologies SHR-HR

Submersible Sewage Pump

Single Seal, Single Phase, & Three Phase Power

OPERATION MANUAL

Dated: 11/27/2017

Document Name: SHR-HR_OM.indd

Page 2 of 8

www.ionproducts.net

All pumps can be used for normal sewage duty where 

extra capacity is required.

All of the pumps are of the recessed impeller type 

that provides a clear volute passage for solids as no 

solids pass through the impeller.

All of the pumps listed can be used to pump septic 

tank  effluent  or  ground  sewage  as  used  in  some 

pressure sewer systems.

WARNING: 

These pumps are not approved 

for, and should not be used in swimming 

pools, fountains or marine areas.

A sewage pump is air locked if water traps air in the 

pump and it cannot get out, thus preventing the pump 

from operating.

In installations of this type a 1/8" hole should be 

drilled in the discharge pipe below the check valve. 

The check valve should be 12 to 18 inches above 

pump discharge.  Do not put check valve directly into 

pump discharge opening.

All single phase pump motors are of the permanent 

split capacitor type that do not require a start switch 

or start relay.

Automatic reset overload switches are attached 

directly to the motor windings.

Three phase pump motors are squirrel cage induction 

type.

Pumps can be installed inside sealed basins with 

proper venting for either simplex or duplex systems. 

Pumps can be installed in a compartment of septic 

tanks for pumping to pressure sewer mains, gravity 

Recessed Impellers

Air Locking

Motor Types

Installation

sewers, leach fields, or evaporation mounds.

WARNING: 

Basin must be vented in 

accordance with local plumbing codes.  These 

pumps are not designed for and CANNOT be installed 

in  locations  classified  as  hazardous  in  accordance 

with the National Electric Code ANSI/NFPA 70.

Pumps are fitted with 2" female threaded pipe flange.  

Galvanized or PVC plastic pipe can be used. Plastic 

pipe is preferred for raw sewage or septic tank 

effluent.

All pumps must have check valves and shut-off valves 

in the discharge line. Check valves must be flapper 

type with outside spring or ball type. Shut-off valves 

can be ball or gate type. Plastic construction for both 

check or shut-off valves is acceptable.

WARNING: 

Always have electrician make 

electrical checks.

CAUTION:

 never work on pumps or control 

boxes  until  circuit  breakers  are  turned  off. 

Always  have  a  qualified  electrician  make  electrical 

connections and service checks.

The following are special instructions for 3-Phase 

pumps.

WARNING:

  Only  qualified  persons  shall 

conduct services and installations of this 

pump.  The  pump  must  be  wired  by  a  qualified 

electrician,  using  an  approved  starter  box  and 

switching device..

CAUTION: 

Risk of electric shock. Do not 

remove cord and strain relief. Do not connect 

conduit to pump.

Three phase pumps are always installed with control 

boxes  having  magnetic  starters  with  3-leg  overload 

protection. Do not try to run three phase pumps 

Piping

Check & Shut-Off Valves

Special Instructions

Содержание SHR series

Страница 1: ...n connected to system WARNING Risk of Asphyxiation Installer s and or service personnel must use proper personal protective equipment and follow OSHA 29 CFR 1910 146 or OSHA 29 CFR 1926 Pump may be installed in a location classified by as a confined space WARNING Risk of fire or explosion Do not smoke or use open flames in or around this system This system is not intended for use in hazardous loca...

Страница 2: ...ompartment of septic tanks for pumping to pressure sewer mains gravity Recessed Impellers Air Locking Motor Types Installation sewers leach fields or evaporation mounds WARNING Basin must be vented in accordance with local plumbing codes These pumps are not designed for and CANNOT be installed in locations classified as hazardous in accordance with the National Electric Code ANSI NFPA 70 Pumps are...

Страница 3: ...ast of impeller can be seen WARNING Never put hand or fingers on the impeller Interchange any two line leads at the magnetic starter to change rotation Pump does not run or start when water is up in tank 1 Check for blown fuse or tripped circuit breaker 2 Check for burned out motor Occasionally lightning can damage a motor even with lightning protection 3 Where plug in cords are used be sure conta...

Страница 4: ...logies SHR HR Submersible Sewage Pump Single Seal Single Phase Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 4 of 8 www ionproducts net MSP SHR Dimensions MSP HR Dimensions ...

Страница 5: ...ogies SHR HR Submersible Sewage Pump Single Seal Single Phase Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 5 of 8 www ionproducts net MSP HR Performance MSP SHR Performance ...

Страница 6: ... Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 6 of 8 www ionproducts net Wiring Diagrams Voltage Black White Red Together 230 1 7 2 8 3 9 4 5 6 Leads 3 Phase Dual Voltage Winding 230 V 3 Phase 230 V 3 Phase 1 2 HP 230 V 1 Phase P S C ...

Страница 7: ...Ion Technologies SHR HR Submersible Sewage Pump Single Seal Single Phase Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 7 of 8 www ionproducts net Notes ...

Страница 8: ...o actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above 3...

Отзывы: