Ion Technologies SHR-HR
Submersible Sewage Pump
Single Seal, Single Phase, & Three Phase Power
OPERATION MANUAL
Dated: 11/27/2017
Document Name: SHR-HR_OM.indd
Page 2 of 8
www.ionproducts.net
All pumps can be used for normal sewage duty where
extra capacity is required.
All of the pumps are of the recessed impeller type
that provides a clear volute passage for solids as no
solids pass through the impeller.
All of the pumps listed can be used to pump septic
tank effluent or ground sewage as used in some
pressure sewer systems.
WARNING:
These pumps are not approved
for, and should not be used in swimming
pools, fountains or marine areas.
A sewage pump is air locked if water traps air in the
pump and it cannot get out, thus preventing the pump
from operating.
In installations of this type a 1/8" hole should be
drilled in the discharge pipe below the check valve.
The check valve should be 12 to 18 inches above
pump discharge. Do not put check valve directly into
pump discharge opening.
All single phase pump motors are of the permanent
split capacitor type that do not require a start switch
or start relay.
Automatic reset overload switches are attached
directly to the motor windings.
Three phase pump motors are squirrel cage induction
type.
Pumps can be installed inside sealed basins with
proper venting for either simplex or duplex systems.
Pumps can be installed in a compartment of septic
tanks for pumping to pressure sewer mains, gravity
Recessed Impellers
Air Locking
Motor Types
Installation
sewers, leach fields, or evaporation mounds.
WARNING:
Basin must be vented in
accordance with local plumbing codes. These
pumps are not designed for and CANNOT be installed
in locations classified as hazardous in accordance
with the National Electric Code ANSI/NFPA 70.
Pumps are fitted with 2" female threaded pipe flange.
Galvanized or PVC plastic pipe can be used. Plastic
pipe is preferred for raw sewage or septic tank
effluent.
All pumps must have check valves and shut-off valves
in the discharge line. Check valves must be flapper
type with outside spring or ball type. Shut-off valves
can be ball or gate type. Plastic construction for both
check or shut-off valves is acceptable.
WARNING:
Always have electrician make
electrical checks.
CAUTION:
never work on pumps or control
boxes until circuit breakers are turned off.
Always have a qualified electrician make electrical
connections and service checks.
The following are special instructions for 3-Phase
pumps.
WARNING:
Only qualified persons shall
conduct services and installations of this
pump. The pump must be wired by a qualified
electrician, using an approved starter box and
switching device..
CAUTION:
Risk of electric shock. Do not
remove cord and strain relief. Do not connect
conduit to pump.
Three phase pumps are always installed with control
boxes having magnetic starters with 3-leg overload
protection. Do not try to run three phase pumps
Piping
Check & Shut-Off Valves
Special Instructions